EasyManua.ls Logo

Hayward H150FD - Consumer Operation & Maintenance; Maintaining Proper Water Chemistry

Hayward H150FD
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Pomona, CA Clemmons, NC Nashville, TN
Tel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
8
SECTION II. CONSUMER OPERATION & MAINTENANCE
TheheatexchangerinyourHaywardpoolheaterismadefromthehighestqualityofcopperandnickel
(Cupronickel)materials.Thepremiummaterialsandtheexactingprocessesusedinthemanufactureofthe
heatexchangerisstateoftheartinpoolheaterdesignandmanufacture.Yet,itremainsvitalthattheheatex-
changerbeprotectedfromdamagingorcorrosivechemicals,insufcientwateroworimproperlybalanced
waterchemistry.Heatexchangerdamageorfailureresultingfromimproperow,improperlybalancedpool
waterortheimproperadditionofsanitizersintothewaterisNOTcoveredunderthetermsofyourwarranty.
Thefollowingfactorsarecriticaltoheatexchangerprotection.Followtheseguidelinestohelpprevent
pre-maturedamageorfailuretoyourheaterandheatexchanger.
1. WATER FLOW THROUGH HEATER
Watermustbeowingthroughtheheaterattheminimumratedowrateduringoperation.Checkthat
thepumpisoperatingandthesystemislledwithwaterandpurgedofallairpriortostartingtheheater.The
minimumratedowratesarelistedintheinstallationmanualonpage25.Someinstallationsmayrequirean
adjustmenttothewaterpressureswitchforproperlow-owprotection.Testyoursystemandifnecessary,
adjustthewaterpressureswitchasdescribedintheinstallationmanualonpage34.
2. POOL/SPA WATER CHEMISTRY
Thechemistrybalanceandmineralcontentofswimmingpoolwaterchangesdailyduetotheadditionof
poolandsanitizingchemicals,batherloads,rain,runoffandtheamountofsun-tonameafew.Improperchem-
istrybalanceandmineralcontentcancausescalinganddepositstoformonpoolwalls,intheltrationsystem,
intheheatexchangertubesandadditionallycanpromotecorrosiveactiontoallmetalsinthewaterpath.Chang-
ingspawaterregularlyandmaintainingthecorrectchemicalbalanceinyourpool/spawillkeepthepool/spa
safeandsanitary,andwillhelpprotecttheheatexchanger.Usea4-waypool/spawatertestkittocheckyour
waterfrequently(atleastweekly).Usethefollowingguidelinestohelpprotectyourheatersheatexchanger:
3. SKIMMER CHLORINATION
Placingchlorineorbrominetabletsdirectlyintotheskimmermayresultinhighchemicalconcentrations
owingthroughtheheater.DONOTplacechlorineorbrominetabletsintheskimmer.
WARNING:
Failure to Maintain Proper Water Chemistry May Cause
Premature Heat Exchanger Damage or Failure
MAINTAINING PROPER WATER CHEMISTRY
Recommended
Level
Effect of Low Levels Effect of High Levels
Chlorine
1 - 3 ppm
Bromine
2 - 4 ppm
pH
7.4 - 7.6
corrosive to heat exchanger,
swimmer irritation
cloudy water, scaling of heat exchanger,
reduced sanitizer effectiveness
Total Alkalinity
80 - 120 ppm
corrosive to heat exchanger,
large fluctuations in pH
scaling of heat exchanger
Calcium Hardness
200 - 400 ppm corrosive to heat exchangerscaling of heat exchanger
Salt
2700 - 3400 ppm poor salt chlorinator performancecorrosive to heat exchanger
hazy water, algea growth,
bacteria causing infections
swimmer irritation, bleaching of clothes/hair,
corrosive to heat exchanger

Other manuals for Hayward H150FD

Related product manuals