EasyManua.ls Logo

Hayward HCC 2000 User Manual

Hayward HCC 2000
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
\
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
HCC 2000
Automated Controller
Owners Manual
092460 RevG
HCC2000
HCC2000-AQ
HCC2000-AU
W3HCC2000
Contents
Introduction............................................3
Installation..............................................5
Pool Chemistry .......................................7
Conguration..........................................8
Display Functions..................................15
System Maintenance.............................17
Troubleshooting....................................19
Warranty...............................................22
®
Hayward Industries
400 Connell Drive, Suite 6100
Berkeley Heights, NJ 07922
Phone: (908) 355-7995
www.hayward.com
Question and Answer IconNeed help?

Do you have a question about the Hayward HCC 2000 and is the answer not in the manual?

Hayward HCC 2000 Specifications

General IconGeneral
BrandHayward
ModelHCC 2000
CategoryController
LanguageEnglish

Summary

Important Safety Instructions

General Safety Precautions

Key safety warnings and recommendations for operating the controller and related equipment.

Foreword

Introduction to HCC 2000

Product Overview and Benefits

Explains the advantages of automated chemical control and compares manual vs. automated methods.

HCC 2000 Components and Tools

Package Contents

Lists all components included in the HCC 2000 controller package.

Required Tools for Installation

Lists the necessary tools for installing the HCC 2000 controller.

Installation Guide

Installation Procedure Steps

Details the step-by-step process for physically installing the HCC 2000 controller.

Pool Chemistry Guidelines

Configuration - Basic Settings

Controller Interface and Button Layout

Identifies buttons and displays on the HCC 2000 controller unit for operation.

Acid/Base Feed Mode Selection

Explains fundamental settings like acid/base feed mode selection for pH control.

Configuration - Setpoints and Calibration

pH Calibration and Setpoint Adjustment

Guides on calibrating and adjusting the pH setpoint for water control.

ORP Setpoint Adjustment

Details how to adjust the ORP setpoint to maintain desired sanitizer levels.

Configuration - Feed Mode Operations

Manual and Automatic Feed Control

Describes manual and automatic control options for pH and ORP chemical feeders.

Advanced Configuration Overview

Introduces advanced programming features usually set during dealer setup.

Configuration - pH Settings

Power On Display and Setup Entry

Explains the display at power-on and how to enter advanced setup modes.

pH Feed Mode, Priority, and Interlock

Configures pH feed mode, pH priority, and pH interlock features.

Configuration - pH and ORP Advanced Parameters

pH Proportional Feed and Alarm Settings

Sets pH proportional feed and high alarm limit for pH monitoring.

ORP Proportional Feed and Overfeed Timer

Configures ORP proportional feed and overfeed timer settings.

Configuration - pH Timers and Other Features

pH Overfeed Timer and Low Alarm Limits

Configures pH overfeed timer limits and low alarm point for pH.

Demonstration, Alarm, and Serial Interface

Covers demo mode, audible alarm, and serial interface settings.

Configuration - ORP Timers and Communication

ORP Overfeed Timer and Alarm Limits

Configures ORP overfeed timer and low/high alarm limits for ORP.

Communication and Printer Setup

Configures online communication and printer output for data logging.

Display Functions - pH Indicators

pH Indicator and Display Details

Explains pH feed, alarm, digital display, and mode indicators on the controller.

Display Functions - ORP Indicators

ORP Indicator and Display Details

Explains ORP feed, alarm, digital display, and mode indicators on the controller.

Indicator Designations Summary

Provides a table summarizing all indicator designations and their functions.

System Maintenance

Water Chemistry and Calibration

Guidelines for testing, recording water chemistry, and periodic pH calibration.

Sensor Maintenance and Cleaning

Instructions for cleaning and maintaining pH and ORP sensors for optimal performance.

System Maintenance - Storage and Replacement

Sensor Replacement and Storage

Information on replacing sensors and proper storage to prevent drying.

Controller Storage and Winterization

Guidance on controller storage, protection from ESD, and winterization.

Troubleshooting Guide

Common Malfunctions and Initial Solutions

Addresses issues like no lights, alarms, illogical readings, and feeder activation problems.

Troubleshooting - Advanced Issues and Specs

Sensor Response and Feeder Operation Issues

Solutions for inconsistent readings, continuous feeding, and over/under shooting setpoints.

Technical Specifications Overview

Lists display ranges, setpoint ranges, default settings, and mode selections.

Technical Specifications - System Details

Safety Systems and Sensor Requirements

Details safety systems, sensor casing, junction type, and output signal requirements.

Power Input, Outputs, and Optional Equipment

Covers power input, output specifications, and optional equipment like feed pumps.

Warranty Information

Warranty Coverage and Claims Process

Outlines the HCC 2000 warranty period, coverage, and how to submit claims.

Extended Warranty Registration

Related product manuals