EasyManua.ls Logo

Hayward HP70HA2 - User Manual

Hayward HP70HA2
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
51300022501 RevE
Hayward Industries
1415 Vantage Park Dr., Suite 400
Charlotte, NC 28203
Phone: (908) 355-7995
www.hayward.com
HP50HA2/HP70HA2 Heat Pump
Installation and Operation Manual
HP50HA2
HP70HA2
Contents
Safety Instructions...............1
Getting Started....................2
Installation..........................9
Water Piping.......................11
Electrical Connections........14
Check Out & Start-Up..........16
Maintenance & Service.......24
Troubleshooting................26
Above Ground & In Ground Pool/Spa Heater

Questions and Answers

  • J
    John Rogers DVMAug 10, 2025
    How to troubleshoot a Hayward HP70HA2 Heat Pump that is not operating?
    • H
      hoffmandustinAug 10, 2025
      If your Hayward Heat Pump isn't operating, first ensure the power is on and check the breaker. If tripped, reset it. Make sure the thermostat is set high enough for the unit to turn on, and that the 3-minute compressor delay has passed. Check for low water flow by ensuring the filter is clean, the filter pump is on, and cleaning devices are unhooked. Also, verify the outside temperature is within the operating range. If the fan isn't working, call for service.
  • R
    Ronald GregoryAug 15, 2025
    What to do if the Hayward Heat Pump is running but Display LEDs are not on?
    • W
      William WangAug 15, 2025
      If the display LEDs on your Hayward Heat Pump are not on while the unit is running, this indicates a system component failure, and you should call for service.
  • H
    hannaryanAug 21, 2025
    Why does my Hayward HP70HA2 run continually?
    • M
      moorechristineAug 21, 2025
      If your Hayward Heat Pump runs continually, the thermostat might be set too high for the ambient temperature; try turning it down. The evaporator could be dirty; clean it by running tap water over the coil without any nozzle attachment. Avoid using pressurized water. If these steps don't help and you suspect an electrical component failure, turn off the pump. If the unit continues running after 3 minutes, turn off the power and call for service.
  • M
    Matthew HornAug 28, 2025
    What to do if water is coming from the bottom of my Hayward Heat Pump?
    • C
      Christian GreenAug 28, 2025
      If water is coming from the bottom of your Hayward Heat Pump, it might be condensation, which is normal. However, to check for a possible water leak, turn the unit off for several hours but leave the filter pump running. If the water quantity decreases, it's likely just condensation; otherwise, a leak might be present.
  • V
    Vernon StevensSep 3, 2025
    Why is my Hayward Heat Pump cycling (on / off too quickly)?
    • L
      lesterjoseSep 3, 2025
      If your Hayward Heat Pump is cycling on and off too quickly, ensure sufficient water flow by checking if the filter pump is running continually. If the cycling continues, turn the unit off to prevent compressor damage. Also, inspect the evaporator coil for severe frost, which could indicate low refrigerant, low ambient temperature, or high humidity with low ambient temperature. If cycling persists, turn the unit off and call for service.

Summary

Important Safety Instructions

Getting Started

Installation

Materials and Location for Installation

Lists required materials and guidance on optimal placement for the heat pump.

Outdoor Installation and Service Clearances

Details required clearances around the unit for installation and service access.

Piping, Drainage, and Anchoring

Covers water piping, condensation drainage, and securing the unit.

Electrical Connections

Outlines power supply connection requirements and remote control interface.

Hayward Omni Connectivity (HP70 HA2 Only)

Omni Configuration and Operation

Guides users through setting up and operating the heater via the Omni control system.

Check-out, Start-Up, and Operation

Interface Overview

Introduces the control panel, its display, and basic functions.

Controller Operation Modes and Settings

Guides on powering, setting temperature, changing modes, locking interface, and using timers.

Bypass Operation

Details on enabling and configuring the bypass operation feature.

Maintenance & Service

Periodic Inspection and Water Chemistry

Recommends regular checks and highlights the importance of water chemistry.

Seasonal Maintenance Procedures

Covers draining the heat exchanger and spring start-up procedures.

Troubleshooting and Error Codes

Troubleshooting Lookup Chart

Provides a guide to identify problems and their potential solutions.

Electronic and Board Error Code Reference

Lists and explains electronic control and frequency conversion board fault codes.

Hayward HP70HA2 Specifications

General IconGeneral
BrandHayward
ModelHP70HA2
CategoryHeat Pump
LanguageEnglish

Related product manuals