Pos: 22 /Technische Dokumentation/Betriebsanleitungen/Empfänger/Elektrischer Anschluss - Kontroll-Lampenfeld @ 10\mod_1398244692035_48.docx @ 122060 @ 11 @ 1
Electrical Connection
Depending on the version, the radio receiver is connected to the machine electronics either via a cable
gland or with a Harting plug connection.
Please observe that the receiver may only be connected to the supply voltage indicated on the type plate!
Warning – shock hazard!
x
The electrical connection may only be carried out by skilled personnel.
x
The electrical connection must comply with the enclosed wiring diagram.
x Switch off the supply voltage before opening the receiver. There is a risk of fatality from touching
live parts inside the housing!
Control Display
A control display with LEDs indicating the operating status of the radio system is located in the upper
housing part.
The LEDs have the following meaning:
Control display
Meaning
Color
Receiver
On
yellow
Illuminates as soon as the receiver is connected to the
supply voltage.
RF
red
Illuminates as soon as the radio connection is interrupted.
Si1
green
Illuminates as soon as the E
-STOP relays are closed.
Si2
green
Illuminates as soon as a drive command is output.
Feedback
yellow
Off
.
(Not available for FSE 508 / 509 / 512.)
Control display
(Data are transmitted in both directions.
Meaning
Color
Receiver
On
yellow
Illuminates as soon as the receiver is connected to the
supply voltage.
RF
red
Illuminates as soon as the radio connection is interrupted.
Si1
green
Illuminates as soon as the E
-STOP relays are closed.
Si2
green
Illuminates as soon as a drive command is output.
Feedback
yellow
Illuminates as soon as a feedback telegram is transmitted.
(Not available for FSE 508 / 509 / 512.)