WE2108S
WE2108M
WE2108
A1632-2.0 en
Scale electronic unit
(NAWI)
WE2108...
(P83...P85)
Reference Manual

Table of Contents

Questions and Answers:

HBM WE2108 Series Specifications

General IconGeneral
Accuracy classIII
Maximum number of verification intervals3000
Minimum load cell impedance350 Ω
MaterialStainless steel
DisplayLCD
InterfaceRS-232

Summary

Safety Instructions

Typographic Conventions

Commissioning

Notes on Cabling

Information regarding the proper use of voltage supply cables and shielding.

Short Description

Scope of Supply

Details on the items included in the original packaging for WE2108 units.

Operating Elements

Description of the functions of the keys on the WE2108 control panel.

Connections

Load Cell Connection

Details on wiring the load cell, including terminal assignments and cable preparation.

RS-232 Interface (Only RS-232 Versions)

Configuration and pin assignment for the RS-232 serial interface.

Installation

Wall Mounting (WE2108 in a Plastic Housing)

Instructions for mounting the WE2108 unit on a wall using its housing design.

Mounting on a Stand (WE2108 in a Plastic Housing)

Procedure for mounting the WE2108 unit on a stand for free-standing scales.

Operation

Basic Functions

Covers essential operations like switching on/off, zeroing, taring, and display modes.

Menu Operation

Detailed guide on navigating the WE2108's menu structure and parameter settings.

Explanations for the Settings

Display Limits

Explanation of how display limits are set based on the scale standard and nominal value.

Tare Value

How the tare function operates and how manual tare values are activated and used.

Calibration

Calibration (Standard Method)

Step-by-step guide for performing a two-point calibration with zero and final values.

Calibration with Linearization

Advanced calibration methods to correct linearity errors in scale attachments.

Influence of the Geographical Installation Site

Access Authorization

Selection of Suitable Load Cells

Supply Voltage and Measuring Signal

Requirements for load cell supply voltage and output signal span for optimal performance.

Dead Load and Nominal Value

How dead load and nominal values affect calibration and scale design.

Further Functions

Filtering

Explanation of analog and digital filter functions for achieving stable measurements.

Printing Function

Setup and usage of the printing function for outputting weight data and additional information.

Troubleshooting

Specifications

Specifications WE2108 in ABS-housing

Technical specifications for the WE2108 unit with an ABS housing.

Dimensions WE2108 in ABS-housing

Dimensional drawings and measurements for the WE2108 unit in ABS housing.

Specifications WE2108S/WE2108M in Steel-housing

Technical specifications for WE2108S/WE2108M units in steel housing.