P/N UM402LB REV20190501
1
402LB
Physician Beam Scale
User Instructions
PELSTAR, LLC 9500 West 55th St. McCook, IL 60525-7110 USA www.homscales.com
Health o meter
®
Professional 402LB
© Pelstar, LLC 2019
0459

Questions and Answers

  • A
    Andrew RivasJul 28, 2025
    Why is my Healt o meter 402LB Scales not accurately measuring weight?
    • J
      Jessica FergusonJul 28, 2025
      If your Healt o meter Scales are not accurately measuring weight, it could be due to a calibration issue. To recalibrate, loosen the lock screw at the end of the long lever in the base with a ¾” hexagon socket wrench. Move it outward to decrease the indicated weight or inward to increase it. A one-sixteenth inch movement of the screw will change the indicated weight by approximately one-quarter pound per 100 pounds.
  • C
    Crystal RossAug 3, 2025
    What to do if the beam does not move at all during weighing process on Healt o meter 402LB?
    • A
      Aaron StuartAug 3, 2025
      If the beam on your Healt o meter Scales doesn't move during weighing, try resetting the weights to a lower setting. Also, ensure the steel rod is properly connected.
  • A
    andersonjoannaAug 8, 2025
    How to fix questionable weight on Healt o meter 402LB?
    • C
      Cheryl FranklinAug 9, 2025
      If you're getting questionable weight readings, or the scale doesn't center equally in the trig loop when the poise weight is at “0”, it may be due to the bar not being properly balanced at “0”. The balance ball must be adjusted so the pointer rests in the center of the trig-loop when both poise weights are at “0”. Make sure the upper and lower poise weights are firmly against the shoulder of the beam. Adjust the balance ball screw by turning the screw at the left end of the bar.
  • S
    sosasarahAug 14, 2025
    What to do if the bar does not move freely on Healt o meter 402LB?
    • C
      curryericAug 14, 2025
      If the bar on your Healt o meter Scales isn't moving freely, it might be sticking or need adjustment. Check if the pointer is touching the side of the trig loop as it moves. If it is, the beam may need to be realigned. Also, make sure the upper and lower poise weights are firmly against the shoulder of the beam. Adjust the balance ball screw by turning the screw at the left end of the bar.
  • B
    brandy31Aug 21, 2025
    Why is the platform rocking excessively on my Healt o meter 402LB Scales?
    • M
      Michael StrongAug 21, 2025
      If the platform of your Healt o meter Scales rocks excessively or touches the base at any corner, it's likely that the base is out of alignment. Follow the base alignment instructions.

Summary

Cautions and Warnings

Intended Use

Specifies the intended purpose and limitations of the scale for professional medical environments.

Patient;Caregiver Safety

Outlines critical safety measures for patients and caregivers during use.

Specifications, Certifications, and Service

Scale Specifications

Details the physical dimensions, capacity, environmental operating conditions, and weight.

Certification Descriptions

Explains the ISO 13485:2016 certification and CE marking requirements.

Scale Disposal

Provides guidance on the proper disposal of the scale according to regulations.

Customer Service Information

Lists contact details for customer support, telephone, and email for inquiries.

Assembly Instructions

Parts List

Lists all components included in the scale's packaging for assembly.

Tools Required

Specifies the tools needed for the assembly process, including the included wrench.

Operating Instructions

Zero Balance Adjustment

Details the procedure for zero balancing the scale before initial use and periodically.

Weighing Instructions

Guides the user on how to correctly weigh a patient using the scale's poise weights.

Height Measurement Instructions

Transportation

Wheel Bracket Installation

Provides step-by-step instructions for installing the optional wheel bracket.

Troubleshooting

Base Alignment Instructions

Detailed steps for adjusting the scale's base to ensure proper alignment and stability.

Maintenance and Cleaning

Cleaning and Disinfecting

Provides instructions for cleaning and disinfecting the scale using recommended solutions.

Replacement Parts

Lists part numbers, descriptions, and units of measure for available replacement parts.

Warranty

10-Year Limited Warranty Coverage

Details the scope of the 10-year limited warranty against defects in materials and workmanship.

Warranty Eligibility

Outlines who is covered by the warranty and the requirement for proof of purchase.

Warranty Exclusions

Specifies conditions and types of damage that are not protected by the warranty.

Healt o meter 402LB Specifications

General IconGeneral
BrandHealt o meter
Model402LB
CategoryScales
LanguageEnglish

Related product manuals