FEATURES
Bright, energy saving LED light
DualBrite® technology
Creep Zone™ technology
Automatically comes on when motion is detected.
UNPACKING
Be sure to remove all contents from packaging and verify
all items are present before assembling this light xture.
is package includes the following items:
Security Light
Owners Manual
Mounting Hardware
© 2016 HeathCo LLC 208802-02A
Motion Sensor
Light Control
Model: 5872
HARDWARE INCLUDED
Note: Six mounting bracket screws are included. e installation will only require two. Discard the unused mounting
bracket screws after installation.
Plastic plug #6 Mounting Bracket #8 Mounting Bracket
Screw (x2) Screw (x2)
Mounting Bolt Mounting Bolt (Pre-Installed in Light Fixture)
FRONT
Mounting Bracket Mini Screwdriver
240°

Questions and Answers

  • S
    Scott DunnJul 27, 2025
    How to fix a Health Zenith Accessory light that won't turn on?
    • A
      Amy BarrettJul 27, 2025
      If the Health Zenith Accessory light won't turn on, first ensure the light switch is on. Check if a fuse is blown or a circuit breaker is off, and replace the fuse or turn the breaker on if needed. If it's daytime, the photocell might be in effect, so recheck after dark. For new installations, verify the wiring is correct. Adjust the motion sensor to cover the desired area. If the outside air temperature is close to body heat, increase the “SENS” setting.
  • E
    Elizabeth WardJul 31, 2025
    Why do my Health Zenith 5872 lights stay on all the time?
    • D
      Dawn CraneJul 31, 2025
      If your Health Zenith Accessory lights are staying on, the motion sensor might be picking up a heat source. Try decreasing the “SENS” setting or repositioning the motion sensor. Also, ensure the motion sensor is not in manual mode by setting the ON-TIME switch to 1, 5, or 20 minutes and following the Manual Mode instructions on page 5 to reset. Make sure the light fixture isn't wired through a dimmer or timer; if it is, replace it with a standard on/off wall switch. Finally, ensure the light fixture is on a circuit without motors, transformers, or fluorescent bulbs.
  • C
    Christy RichardsonAug 4, 2025
    Why does my Health Zenith 5872 light come on randomly?
    • N
      Noah WangAug 4, 2025
      If your Health Zenith Accessory light is turning on for no apparent reason, the motion sensor may be sensing small animals or automobile traffic. Try decreasing the “SENS” setting or repositioning the motion sensor. If the “SENS” switch is set too high, decrease it. If the “DUALBRITE” switch is in the 3 hour, 6 hour, or dusk-to-dawn setting, the light fixture is operating normally. If the outside temperature is much warmer or cooler than a person’s body heat, decrease the “SENS” setting. Also, if the light fixture is wired through a dimmer or timer, replace it with a standard on/off wall switch.
  • H
    hawkinsmelissaAug 8, 2025
    Why is my Health Zenith 5872 Accessories light turning on during the day?
    • S
      Steven FranklinAug 8, 2025
      If your Health Zenith Accessory light comes on during the day, it may be installed in a relatively dark location, and the light fixture is operating normally under these circumstances. Also, check if the “ON-TIME” switch is in the “TEST” position; if so, set it to the 1, 5, or 20 minute setting.
  • M
    Melissa PetersonAug 13, 2025
    What to do if my Health Zenith Accessories lights are flashing on and off?
    • M
      Mrs. Tara PaceAug 13, 2025
      If the Health Zenith Accessory lights are flashing on and off, it could be due to heat or light from the lamp heads turning the motion sensor on and off; reposition the lamp heads away from the motion sensor. Reflected heat from other objects may also trigger the sensor; decrease the “SENS” setting or reposition the motion sensor. If the motion sensor is in “TEST” mode, the light only stays on for 8 seconds; set the ON-TIME switch to 1, 5, or 20 minutes.
  • M
    Meghan MannAug 17, 2025
    Why do my Health Zenith 5872 Accessories lights turn off too late in Dusk-to-Dawn setting?
    • S
      Sergio TownsendAug 17, 2025
      If the Health Zenith Accessory lights turn off too late in Dusk-to-Dawn setting, the light fixture may be installed in a relatively dark location. Relocate the light fixture or use the 3 hour or 6 hour setting.
  • J
    James AdamsAug 22, 2025
    What to do if my Health Zenith 5872 lights flash once then stay off in manual mode?
    • N
      nancycannonAug 22, 2025
      If the Health Zenith Accessory lights flash once then stay off in manual mode, the motion sensor is likely detecting light from the lamp heads. Reposition the lamp heads to keep the area below the motion sensor relatively dark.

Summary

Product Overview and Features

Key Product Features

Details the main capabilities: energy-saving LED, DualBrite, Creep Zone, and automatic motion detection.

Unpacking and Contents Verification

Instructions for unpacking the fixture and verifying all included items are present.

Identification of Included Hardware

Visual guide to identify all components of the mounting hardware.

Safety and Installation Guidance

Critical Safety Warnings

Essential precautions for preventing electric shock, fire, and other hazards during installation.

Installation Requirements and Notes

Electrical, mounting, and grounding specifications for proper setup.

Motion Sensor Detection Principles

Explanation of how the motion sensor detects heat movement and its sensitivity.

Installation Procedure Steps

Mounting Plate and Bracket Installation

Detailed steps for attaching the mounting plate and bracket to the junction box.

Electrical Wiring Connections

Guide for connecting the fixture wires to the terminal block and ground screw.

Final Fixture Assembly and Securing

Steps to align and secure the light fixture to the mounting plate.

Testing and Adjustment Procedures

Preparation for Testing

Ensuring power is on and understanding the sensor's warm-up period before testing.

Setting Controls for Initial Test

Configuring SENS, ON-TIME, and DUALBRITE switches for testing.

Adjusting Detection and Coverage Areas

Guidance on physically adjusting the sensor and lamp heads for optimal coverage.

Advanced Features and Modes

Optimal Sensor Aiming Guidelines

Recommendations on what to avoid aiming the sensor at to prevent false triggers.

DualBrite Timer Functionality

Explanation of the accent light level and full brightness activation sequence.

Creep Zone Detection Enhancement

How the Creep Zone feature increases detection coverage near the fixture.

Manual Mode Operation

Instructions on how to toggle manual mode on/off using a wall switch.

Specifications and Troubleshooting

Product Specifications

Technical details including range, sensing angle, power requirements, and modes.

Troubleshooting: Light Not Coming On

Solutions for common issues where the light fails to activate.

Troubleshooting: Light Activation Issues

Addresses problems like light coming on during the day or for no apparent reason.

Troubleshooting Common Issues

Troubleshooting: Lights Turn Off Late

Solutions for lights staying on too long, especially in Dusk-to-Dawn mode.

Troubleshooting: Continuous Light Operation

Addresses the symptom of lights staying on continuously.

Troubleshooting: Flashing Light Behavior

Solutions for lights flashing on/off or flashing then staying off in manual mode.

Technical Support and Warranty

Contacting Technical Service

Information on how to get assistance and contact HeathCo LLC for support.

Five-Year Limited Warranty Details

Explains the terms, coverage, and exclusions of the product's limited warranty.