READ AND SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE
WARNING
Risk of property damage, injury or death.
Installation, adjustments, alterations, service and
maintenance must be performed by a qualified ser-
vice technician.
WARNING
Electric Shock Hazard.
Can cause injury or death.
Disconnect all remote electrical power supplies be-
fore servicing. Unit may have multiple power sup-
plies.
Unit must be connected to a grounded power sup-
ply in accordance with national and local codes.
Principle of Operation
The purpose of the Healthy Climate
®
Whole Home Dehu-
midifier is to keep humidity in the home at acceptable lim-
its, thus reducing the unwanted effects of high humidity.
The dehumidifier gathers data from the HVAC system, or
from the space it is controlling, and measures the condition
of the home air to decide when to run. An integrated air
cycling feature can activate the HVAC blower to cycle air
through the home to balance the indoor conditions. The
dehumidifier can also operate an optional ventilation
damper to bring in outside air.
OWNERS MANUAL
Model HCWH-90 & HCWH-135
Whole Home Dehumidifier
INDOOR AIR QUALITY
506242−01
03/09
Supersedes 02/09
Operating Instruction
The Whole Home Dehumidifier has three adjustable set-
tings: the dryness setting, the air cycle period and the air
cycle time within that period. The dehumidifier dryness can
be set from ˆ1˜ or ˆLESS˜ to ˆ7˜ or ˆMORE˜ based on de-
sired comfort level. Most installations should be initially set
between ˆ3˜ and ˆ5˜ or ˆNORMAL˜ setting; however this
can be adjusted to your individual needs.
Air cycle period is set using the DIP switches, and the po-
tentiometer is used to set the air cycle time which are both
located on the control board under the knob and are set
during installation. If the cycle period is set to 1 hour and
the cycle time potentiometer is set to 20 minutes, you will
get 20 minutes of air cycling every hour. It is important to
understand that the air cycling requirement ˘ 20 minutes
per hour in this example ˘ may be satisfied by a heating,
cooling, or fan call initiated by your thermostat, or if such
calls do not satisfy the air cycling requirement, from a blow-
er call initiated by the dehumidifier itself.
Y2188 Whole Home Dehumidistat (optional)
If your Whole Home Dehumidifier has the optional dehu-
midistat installed, refer to the Whole Home Dehumidistat
Owner’s manual for operation information.
Adjusting Dehumidifier Main Control Set Point
Use the main control knob on the outside of the unit to set
the dehumidifier dryness setting. Start with a ˆNORMAL˜
setting for most installations. Moving the knob clockwise to
ˆMORE˜ will make conditions drier. Moving the knob to-
ward ˆLESS˜ allows for higher moisture levels.
Litho U.S.A.
Question and Answer IconNeed help?

Do you have a question about the Healthy Climate Solutions HCWH-90 and is the answer not in the manual?

Healthy Climate Solutions HCWH-90 Specifications

General IconGeneral
BrandHealthy Climate Solutions
ModelHCWH-90
CategoryDehumidifier
LanguageEnglish

Summary

General Safety Warnings

Risk of Property Damage, Injury or Death

Installation, adjustments, alterations, service, and maintenance must be performed by a qualified service technician.

Electric Shock Hazard

Can cause injury or death. Disconnect all remote electrical power supplies before servicing. Unit may have multiple power supplies.

Principle of Operation

Operating Instructions

Adjusting Dehumidifier Main Control Set Point

Use the main control knob to set the dehumidifier dryness setting, adjusting clockwise for drier conditions or counter-clockwise for higher moisture.

Optional Dehumidistat Y2188

Information for the optional Y2188 Whole Home Dehumidistat, referring to its dedicated owner's manual for operation.

Maintenance Safety

Potential Equipment Malfunction or Damage

May require repairs and/or void warranty. Do not use solvents/cleaners on or near the circuit boards.

Maintenance Procedures

Air Filter

Clean or replace the filter annually. Remove via access panel, clean with warm water and detergent, then reinstall.

Drain Trap

Check and clean the drain trap or outlet annually. Prime with water before start-up and after extended shutdowns.

Outdoor Ventilation Option

Ventilation Control Limits

Damper will not bring in outside air if temp is above 100°F or below 0°F. Specific limits apply for 20°F to 0°F range.