Hearth & Home Technologies • Fireside Burner/Hearth Kits • 4004-318•Rev F 5/2013
7
A. Gas Supply Connection
A 3/8 in. flared fitting has been installed on the gas valve
inlet at the factory. Ensure fittings are of the appropriate size
and type on the gas line connection. If the tubing has to be
cut to length be sure to use the proper cutting and flaring
tool. Also, be careful not to crimp the tubing while bending. If
the tubing becomes crimped, do not use for installation.
Fire Risk
Explosion Risk
Verify inlet pressures.
High pressure may cause over fire
condition.
Low pressure may cause explosion.
Install regulator upstream of valve if line
pressure is greater than 1/2 psig.
WARNING
3
Appliance Preparation
Remove black cap from left side.
Remove two pilot head screws.
Remove two pilot bracket screws.
Detach thermocouple and pilot from control valve.
Remove the control valve from the right side of the burner
pan and replace on left, upside down.
Note: Prior to installing the valve, use Teflon tape or joint
compound on the male threads.
Reinstall pilot bracket on left side of burner.
Reinstall pilot assembly to pilot bracket.
Reattach pilot tube and thermocouple to control valve.
Reinstall black cap removed from left side of burner to
right side.
Install valve shield.
Note: An individual manual shutoff valve (not supplied) is
required when installing this appliance. The manual shutoff
valve must be located in an easily accessible area, no more
than 6 feet from the appliance.
Note: Have the gas supply line installed in accor-
dance with local building codes, if any. If not, follow
Note: A listed (and Commonwealth of Massachusetts
approved) 1/2 in. (13 mm) T-handle manual shut-off valve
and flexible gas connector are connected to the 1/2 in.
(13 mm) control valve inlet.
If substituting for these components, please consult
local codes for compliance.
Shock Risk
Fire Risk
Use ONLY optional accessories approved
for this appliance.
Using non-listed accessories voids
warranty.
Using non-listed accessories may result
in a safety hazard.
Only Hearth & Home Technologies
approved accessories may be used
safely.
WARNING
WARNING
Gas Leak Risk
Support control when attaching pipe to
prevent bending gas line.
Fire Risk
Explosion Risk
Personal Injury Risk
An explosion could occur if a connection is
made directly to an unregulated propane (LP)
tank.
WARNING
Joint compound to Teflon tape must be used on all threaded
male connections to ensure a tight seal.
LP Only
Install new pilot bracket on left side of burner.
Install new pilot assembly to pilot bracket.
Attach pilot tube and thermocouple to control valve.
Install black cap removed from left side of burner to right
side.
Install valve shield.
Natural Only
NOTE: You will need a kit to change to
left side piping. See page 18.
Left side piping when finished
B. Convert to Left Side Piping