Hearthstone Quality Home Heating Products, Inc ® Bari Model 8171
TROUBLESHOOTING GUIDE
Fully open the primary air control one minute before
opening doors.
Preheat the chimney when first starting a fire. Briefly open a
window in the room containing the stove.
Examine the chimney and stovepipe for blockage or
creosote accumulations.
Reline the chimney to the appropriate diameter
Install a draft inducer or replace the chimney.
Air Infiltration Into The
Chimney
Seal chimney connections and openings such as clean-out
doors.
Appliance Connected to
Disconnect all other appliances and seal openings.
OR GAS
Fully open the primary air control one minute before
opening the door and keep it fully open for a few minutes
Burn the stove at a higher burn rate.
Empty the ash pan more frequently. Increase efficiency of
burns, and avoid using poor quality or green wood.
UNCONTROLLED
OR SHORT BURN
Unsealed or Open Door
Open ash grate
Close the door tightly or replace the gaskets.
Slide ash grate to closed position.
Check the installation. Operate at LOW BURN. Install
stovepipe damper.
Shorten the chimney. Install stovepipe damper(s).
Reline the chimney to the proper diameter.
High Winds or Hilltop
Location:
Draft in excess of 0.1 WC should be corrected with a
stovepipe damper(s)
Poor Quality or Green
Wood
Use only air-dried wood, preferably dried at least one year.
Operate the stove at a higher burn rate.
Replace with a pre-fabricated insulated chimney system or
a properly sized masonry chimney.
Reline or insulate the chimney.
Leaky Stovepipe or
Chimney
Too Much Heat Loss
From House
Add insulation, use energy efficient windows, or caulk
windows, and seal openings in home.
Empty the ash pan more frequently. Increase efficiency of
burns, and avoid using poor quality or green wood.
Do not over-fire the stove. Monitor stove temperatures. Use
seasoned wood only.
Check the DRAFT. A damper may be required. Operate the
stove at a LOW BURN range.