Installation and Assembly
Your appliance is a wall-mounted, recessed and /or mantel installed appliance. Select a suitable location that is
not susceptible to moisture and is away from drapes, furniture and high traffic areas.
NOTE
Follow all National and local electrical codes.
MINIMUM CLEARANCE TO COMBUSTIBLES
Measurements are taken from the glass front.
Bottom 0” Top 8”(300mm) to mantel
Sides 0” Top 8”(300mm) to ceiling
Back 0”
MINUMUM MANTEL CLEARANCES
WARNING
WHEN USING PAINT OR LACQUER TO FINISH THE MANTEL, THE PAINT OR LACQUER MUST
BE HEAT RESISTANT TO PREVENT DISCOLOURATION
IF-1380
80”
203.2cm
17”
43.2cm
5.51”
14.0cm
76.285”
193.75cm
16.25”
41.27cm
9.13”
23.2cm
73.7”
187.2cm