EasyManua.ls Logo

Heat Controller DXM2 User Manual

Heat Controller DXM2
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Heat Controller, Inc. • 1900 Wellworth Ave. • Jackson, MI 49203 • (517)787-2100 • www.heatcontroller.com
APPLICATION, OPERATION
& MAINTENANCE MANUAL
DXM2 Digital
Heat Pump Controller
Question and Answer IconNeed help?

Do you have a question about the Heat Controller DXM2 and is the answer not in the manual?

Heat Controller DXM2 Specifications

General IconGeneral
BrandHeat Controller
ModelDXM2
CategoryController
LanguageEnglish

Summary

DXM2 Overview and Features

General Operating Parameters

General operating parameters for the DXM2 Control including environment and power.

Power Requirements and Relay Ratings

Power requirements and contact ratings for DXM2 relays.

Control Features

Lists basic and advanced control features of the DXM2.

DXM2 Physical Dimensions & Layout

DXM2 Layout and Connections

DXM2 Controls and Operation

Thermostat Compatibility

Recommendations for thermostat compatibility and wiring.

Field Selectable Inputs and Test Mode

Explanation of Test Mode, Retry Mode, and field inputs.

DXM2 DIP Switch Configurations

DIP Package #1 (S1) Settings

DIP 1.1-1.8 settings for unit operation and features.

DIP Package #2 (S2) Settings

Configuration of ACC1 and ACC2 relay options via DIP switches.

DIP Package #3 (S3) Settings

Setup selections for DIP Package #3, including communications and HWG.

DXM2 Fault Codes and Safety Features

Safety Features

Safety features to protect components from damage.

Fault Codes Overview

Explanation of lockout modes and specific fault codes.

DXM2 Fault Codes Details

Fault Codes 6-12

Detailed explanation of fault codes 6 through 12.

Diagnostic Features and Operation

Explanation of status and fault LEDs and unit power up.

DXM2 Unit Operation Modes

Standby, Fan-Only, and Heating Stages

Operation modes for standby, fan-only, and heating stages 1-3.

DXM2 Unit Operation Modes - Advanced

Emergency Heat and Cooling Stages

Operation modes for emergency heat and cooling stages 1-2.

Blower Configurations and ECM Operation

Details on blower types and ECM blower features.

DXM2 Application Notes and Accessory Relays

Hot Water Generator and Proportional Valve Operation

Operation of HWG pump and proportional valves.

Accessory Relay Applications

Notes on configuring accessory relays for specific uses.

DXM2 System Inputs and Thermostat Signals

Thermostat Input Combinations

Table showing demand based on thermostat input combinations.

Night Setback and Override Inputs

Explanation of Night Setback and Override inputs.

DXM2 System Inputs and Outputs

Emergency Shutdown and H Input Functions

Explanation of ESD and H input functions.

Other Outputs and Status LEDs

Description of Electric Heat outputs and status LEDs.

DXM2 Communications and Sensors

Communications Port

Information on the RS485 communications port.

Replacement Thermistors

Part numbers for LT1 and LT2 thermistors.

DXM2 Service & Application Notes

Pressure Switches and Condensate Sensor

Information on pressure switches and condensate sensor.

Thermistor Temperature Sensors

Details on thermistor sensors and their characteristics.

DXM2 Thermostat Details

Thermostat Compatibility and Signals

Recommendations for thermostat compatibility and signals.

Safety Listing

Safety listings for the DXM2 Control.

Basic Troubleshooting Information

General Troubleshooting and Field Inputs

General guidelines for troubleshooting and verifying field inputs.

Sensor Inputs and DXM2 Outputs

How to check sensor inputs and DXM2 outputs.

Test Mode Operation

How to enter and use Test Mode for diagnostics.

Advanced Troubleshooting and Configuration

System Configuration and Airflow Selection

Adjusting configuration and ECM airflow settings.

Option Selection and Unit Configuration

Setting control options and unit configuration parameters.

Heating/Cooling Delays and Loop Configuration

Adjusting delays and setting up loop configuration.

Delta T Settings

Setting target delta T for heating and cooling modes.

Advanced Troubleshooting and Configuration - Service Mode

Service Mode Functions

Installer functions for troubleshooting, diagnostics, and history.

Fault History and Analysis

Retrieving, analyzing, and clearing fault history.

DXM2 Functional Troubleshooting Flow Chart

DXM2 Wiring Diagram: Motorized Modulating Water Valve

DXM2 Wiring Diagram: Standard Installation

Functional Troubleshooting Table

Functional Troubleshooting Table - Further Issues

Performance Troubleshooting Table