HeaterMate HY02TP - Automatic Mode - Weekly Programming; Factory Settings; Temperature Differential to Activate Heater; Temperature Setting Limits

HeaterMate HY02TP
2 pages
Print Icon
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4) Automatic Mode - Weekly Programming
Automatic Mode ( symbol is showing next to SET temperature) allows customer to program up to 6 periods with different
SET temperatures for every weekday and up to 2 periods for the weekend. The table below shows the factory pre-set periods
and their temperatures. If less than 6 periods per day are required, then the adjacent periods can be merged into one period as
illustrated in the Example below. When device is in Automatic Mode, the display will always be ON, showing the current period
icon and its SET temperature.
Explanation
Screen
Press/hold “ ” for 3 seconds then release - screen will
display (6 periods for every week day) and
week days: “ ”. First period will be flashing -
press “ or ”to adjust temperature setting temperature then
press “ ” to adjust time setting. Press “ ”to go to the next
period and so on for all 6 periods for week days. Now press “ ” to
go to weekend programming with 2 periods for “ ” and set
temperatures and times in the same way as for week days. . Press
” when finished. Please refer to the table below for default
values for different periods.
5) Factory Programmed Periods and Settings
Period
Icon
Default Time
Default Temperature
Working Day
1
06:00
20ºC
2
08:00
15ºC
3
11:30
15ºC
4
12:30
15ºC
5
17:30
20ºC
6
22:00
15ºC
Weekend
1
08:00
20ºC
2
23:00
15ºC
Example: Set the heater to come ON at 7pm, maintain room temperature at 20 degrees until 7am, then turn OFF until 1pm,
then at 1 pm to come ON and maintain 22 degrees temperature until 2.30pm, then turn OFF and come ON at 7pm (as above)
and so on, during weekdays:
(i) Set up Period 1 temperature to well below the typical room temperature e.g. to 10 degrees and Period 1 start time to 07:00;
(ii) Move to period 2 and set its temperature also to 10 degrees and leave its start time as default at 08:00 (iii) Repeat the same
for period 3 (iv) Move on to period 4 and set its temperature to 22 degrees and its start time to 13.00; (v) Move on to Period 5
and set its temperature to 10 degrees and its start time as 14.30 (vi) Move on to Period 6 and set its temperature to 20 degrees
and its start time to 19.00; (vii) Make sure the Timer function is disabled 00.00 is set for both ON and OFF times (viii) Make
sure Heatermate is in Automatic mode - symbol is showing next to SET temperature. If not, press SET button once to switch
to Automatic mode. You can now leave your Heatermate and it will do the job.
6) Factory Settings
This section shows how to change factory settings: change from Heating to Cooling mode, adjust the temperature
sensor reading, change the temperature differential to activate your heater (see Section 1 - Operation) etc.
Press/hold for 3 seconds then release to enter into factory settings mode, then press“ to choose the required
option (A1-A9, AA) as per table below. Press“ or ”to adjust value. Press to save and move to the next option.
No.
Display
Setting Option
Data Setting Function
Factory Default
Setting
1
A1
Room Ventilation Function
(Heater is off when window is open)
5-25ºC; 5-60min
Disabled (- - ºC)
2
A2
Temperature Differential to Activate
Heater
1-9ºC
2ºC
3
A3
Temperature Setting - Highest Limit
20-70ºC
35ºC
4
A4
Temperature Setting - Lowest Limit
1-10ºC
5ºC
5
A5
Temperature Sensor Calibration
±5ºC
Factory Calibration
6
A6
Anti-freezing Function turns heater
ON when temperature is below 5ºC
00:Anti-freezing function OFF
01:Anti-freezing function ON
00:Anti-freezing
function OFF
7
A7
Resume operation after power
disconnection
1:Resume operation after
power disconnection
0:Stay turned OFF after
power disconnection
1:Resume operation
after power
disconnection
8
A8
Operational Mode
00:Cooling Mode
01:Heating Mode
01:Heating Mode
9
A9
Programmable or Non-programmable
(Automatic Mode is disabled)
00:Programmable
01:Non-programmable
00:Programmable
10
AA
Return to Factory Settings
88:Do not return to Factory
Settings
00:Return to Factory Settings
N/A
Troubleshooting: If you lost your Heatermate functionality - please return it to its factory settings (#10 in the above table).
TECHNICAL SPECIFICATIONS:
Operating Voltage: 240V , 50HZ
Max Load: 10A, 2400W (resistive)
Temperature Measurement Precision:±1ºC
Temperature Setting Range:1ºC - 70ºC
Self-consumption Power:<0.3W
Temperature Sensor: NTC
NB: Suitable for use with heaters and air conditioners which can automatically restart after power reconnection
WARRANTY: This product comes with 2 years manufacturer warranty please contact your place of purchase for
warranty replacement. For technical support please contact us via info@heatermate.com.au or call us 1800 229 325.