EasyManua.ls Logo

Heathkit IM-18 User Manual

Heathkit IM-18
9 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Assembly
and
‘TABLE
OF
CONTENTS
Operation
of
the
Specifications,
.
.
Introduction,
.
4
Circuit
Description,
Parts
List,
VACUUM
TUBE
VOLTMETER
‘Step-By-Step
Assembly
Tange
Switch
Assembly...
MODEL
IM-18
Front
Panel
Mounting,
Knob
Installation,
Front
Panel
Wiring,
2.
Cireult
Board
Wiring...
Connecting
Cable,
.
.
Wiring
Circuit
Board
To
The
Panel,
‘Mounting
The
Battery
Spring.
.
Meter,
Bracket,
And
Circuit
Board
Installation,
....se0e
ee
Final
Wiring...
+,
Preliminary
Test,
Preparation
Of
Test
Leads,
.
‘Test
And
Calibration,
using
Your
VIVM,
In
Case
Of
Difficulty,
.
.
‘Troubleshooting
Chart...
+.
eeeeeeee
Maintenance,
6.
+
Accessory
Probes,
.
Schematic,
. .
(fold-out
from
page).
....
|33
Replacement
Parts
Price
List,.....+++
[94
HEATH
COMPANY
BENTON
HARBOR,
MICHIGAN
49022
Question and Answer IconNeed help?

Do you have a question about the Heathkit IM-18 and is the answer not in the manual?

Heathkit IM-18 Specifications

General IconGeneral
BrandHeathkit
ModelIM-18
CategoryMeasuring Instruments
LanguageEnglish

Summary

Specifications

Electronic DC Voltmeter

Details specifications for the Electronic DC Voltmeter function.

Electronic AC Voltmeter

Details specifications for the Electronic AC Voltmeter function.

Electronic Ohmmeter

Details specifications for the Electronic Ohmmeter function.

Introduction to the VTVM

Circuit Description

Test and Calibration Procedures

Zero Adjust

Adjusts the meter pointer to zero for DC measurements.

DC Calibration

Calibrates DC voltage readings using a test point.

Ohms Check

Checks ohmmeter function and sets infinity scale.

AC Calibration

Calibrates AC voltage readings.

AC Calibration Without Line Cord Adapter

Procedure for calibrating AC voltage without a line cord adapter.

Aging and Final Calibration

Recommends aging tubes and performing final calibration for accuracy.

Troubleshooting Chart

Completely Inoperative

Steps to diagnose and resolve a completely inoperative instrument.

Inability to Obtain DC Balance

Troubleshooting steps for issues with DC balance.

AC Balance Issues

Procedure for adjusting AC Balance and related issues.

Inaccurate AC Readings

Troubleshooting steps for inaccurate AC voltage readings.

Inaccurate DC Readings

Troubleshooting steps for inaccurate DC voltage readings.

Ohms Inoperative

Troubleshooting steps for the ohmmeter not functioning.

AC Inoperative

Troubleshooting steps for the AC measurement function.

Ohms Inaccurate

Troubleshooting steps for inaccurate ohmmeter readings.

Related product manuals