Do you have a question about the Heatmiser UH4 and is the answer not in the manual?
Details the UH4 as a 4 Zone & Hot water wiring centre for 230v thermostats, controlling actuators/valves and boiler via volt-free output.
Instructions for mounting the UH4 unit onto a DIN rail using provided clips, detailing insertion and locking procedures.
Details the required connections for the 230v AC mains power supply, including fuse rating and terminal identification (L, N, E).
Explains the volt-free switch connections (LS, E, LR) for the main call for heat in the system.
Describes the output for controlling a hot water valve via a cylinder thermostat, including terminal connections and wiring colours.
Details the zone outputs for actuators or valves, explaining terminal connections and correspondence with thermostat wiring.
Emphasizes installation by qualified electricians and reading instructions before applying power to ensure correct wiring.
Details wiring for Underfloor Heating (UFH), Radiator zones, and Hot Water zones using various Heatmiser thermostats.
Explains the function of the Zone 4 manifold pump control switch for underfloor heating or other system configurations.
Notes the requirement for the hot water valve live feed to be connected via a cylinder high limit thermostat.
Illustrates wiring for Underfloor Heating (UFH) and Radiator zones using DS1 and Slimline thermostats with the UH4.
Shows wiring diagrams for connecting Touch, NeoStat, and Smart Stat thermostats to the UH4 for heating and hot water control.
Showcases products commonly used with the UH4 wiring centre, including Slimline, NeoStat, Touch, SmartStat, and DS-1 models.
The Heatmiser UH4 is a versatile wiring center designed for controlling heating systems, specifically tailored for use with Heatmiser 230V thermostats. Its primary function is to manage up to four heating zones and a hot water zone, making it suitable for both underfloor heating and radiator systems.
The UH4 acts as a central hub for your heating system, receiving signals from thermostats and activating the appropriate components such as actuators, valves, boilers, and pumps. It is designed to control any actuator or valve that requires a 230V AC signal to open. For mid-position valves or those needing a closing signal, a changeover relay is required, which the UH4 can accommodate.
One of its key features is the ability to operate a boiler or other heat source through a volt-free output. This ensures compatibility with a wide range of heating systems. Additionally, the UH4 includes a dedicated pump/valve output, which is standard for underfloor heating systems and typically operates a manifold pump or manifold valve.
The hot water (H/W) output provides a 230V enable signal to the hot water valve, with auxiliary wires connected to the Gr & Or terminals. This allows for integrated control of your domestic hot water supply.
A unique aspect of the UH4 is its flexibility regarding Zone 4. This zone can be configured as either an isolated radiator zone or an underfloor heating zone via a Yes/No switch.
Any output not required by your specific system can simply be ignored, offering a streamlined setup.
The UH4 is designed for straightforward installation and integration into your heating system. It can be mounted directly to a wall using four screws or, alternatively, can be DIN rail mounted for a more organized installation within an electrical enclosure. For DIN rail mounting, two clips are provided on the back of the unit. These clips are positioned in the middle and slide down, with points A and B locating into corresponding holes to lock the unit in place. The UH4 is then located onto the DIN rail from the top, the clip is pulled down, and the bottom of the UH4 is pushed onto the DIN rail. Releasing the clip locks the unit securely. To remove the UH4, both clips are pulled down, and the unit is removed from the DIN rail.
The wiring connections are clearly marked for ease of installation.
The manual provides detailed wiring diagrams for various configurations, including:
The UH4 is designed for reliable operation with minimal maintenance.
Overall, the Heatmiser UH4 is a robust and adaptable wiring center, providing comprehensive control for modern heating systems with a focus on ease of installation and reliable performance.
| Zones | 4 |
|---|---|
| Power Supply | 230V AC |
| Mounting | Wall mounted |
| Type | Wiring Centre |
| Power Consumption | 5W |
| Thermostat | Compatible with Heatmiser thermostats |
| Control | Wired |
| IP Rating | IP20 |
| Pump Output | 230V AC, 5A max |
| Boiler Output | 230V AC 50Hz (Max 5A) |