Issued September 2017
End of Day Procedures
Copyright 2017, Heil Environmental
Printed in U.S.A.
147
DuraPack
®
5000
END OF DAY PROCEDURES
Parking the Unit
1. Park the unit in the space designated by your
employer/supervisor.
2. Set the parking brake.
Washout System
If the unit has a washout system and you did not use it at
the landfill/transfer station, you should clean the body and
hopper, unless your employer has a different policy. If your
employer’s policy is different from this manual, follow their
policy.
Final Inspection
Perform a final inspection of the unit:
1. Clear the area of all people.
2. Start the engine if it is not running.
3. Make sure all lights and in-cab control switches
operate correctly.
4. Put the transmission in reverse while you press the
service brake. The backup alarm should sound in the
cab. If the alarm does not sound in the cab, report
this to your employer/supervisor immediately.
5. Check the unit for fluid leaks from the hoses,
cylinders, valves, pump and fittings. Report any leaks
to your employer/supervisor.
6. Make sure all cylinders (except tailgate lock cylinders
and arm raise cylinders) are in their retracted
position.
7. APPLY the parking brake.
8. Put the transmission in neutral and turn the engine
OFF.
9. Put the unit in the Lock-Out/Tag-Out mode .
10.Open the air tank drain valve.
11.Turn the battery disconnect switch to OFF.
12.Follow the company policy for locking the cab doors.
Reports to Employer/Supervisor
Complete any reports required by your employer/
supervisor. If you found any problems during the final
inspection, prepare the necessary report for the employer/
supervisor.
Ignition Keys
Put the ignition keys in a secure storage area designated
by your employer/supervisor.
59

Table of Contents