Illustration 2, Item 1 > the machine is switched on
Illustration 2, Item 2 > the machine is switched off
Always use the pressure switch to switch the machine on and off. Check the switch position
before inserting the battery; the machine must be switched off.
3.7 Malfunctions
The machine possesses an electrical overload and total discharge protection. If the machine
switches itself off during operation, this may be due to one of the following causes:
1. The clipping tension has been set too high and/or the blades are insufficiently oiled. Reduce
the clipping pressure and oil the blades regularly so that they do not run dry. If you still do
not get a satisfactory clip, have the clipper blades resharpened by a specialist workshop.
2. The clipper head is jammed. Remove the blockage.
3. So as to protect the battery from a damaging total discharge, the machine will switch itself
off when the battery is flat. The battery must then be recharged.
Switch off the machine in the event of 1, 2 or 3. After rectifying the cause, the machine can be
used again as usual.
See the list of malfunctions in Section 5, “Repairs”, for the rectification of malfunctions.
Illustr. 2