49
the program stored destroyed. Try to reset the program of
logic card. The fault exists in the microcontroller if the
fault still exists, Change the controller.
Feedback
signal fault of
encoder
Under normal condition, if the target speed is greater
than10 Hz and the rotation speed of motor higher than 1.5
Hz, the feedback signal of encoder checked by controller
should exceed a threshold value. If not, the controller will
give alarm. Test the motor encoder and see if motor or
wiring is normal and if installation correct. Change the
controller if periphery is normal.
Fault of
temperature
sensor
Phenomenon:The output signal of temperature sensor of
motor exceeds the scope.
Solution: Check the value of sensor and connection of
wires and the fault is inside the controller in case of no
problem found.
During software testing, there are many reasons for such
fault such as: CAN communication fault and EEPROM
READ/WRITE ERROR etc. Check the parameter of
“DEBUG MODE”, the value must be “OFF”.
Wrong contents are found when testing the main memory:
The registration address is “DIRTY” and the fault will
restrict the operability of vehicle.
Fault analysis: Switch on the key after switching it off and
change the controller if the trouble still exists.
The fault will be hinted when calibrating the current gain.
No treatment is needed and it will automatically disappear
when calibration is finished.
CAN communication fault between pump and traction.
Check CAN wiring, software setting and edition
information.
It is the time for service and maintenance is needed.
The output signal of temperature sensor of controller
exceeds the range.
The fault has nothing to do with external parts and change
the controller.
During startup, the controller tests if the voltage of battery
is within the nominal scope. Check if the value of
BATTERY VOLTAGE parameter in the menu conforms to
that on the voltmeter. If not, make them conform to each
other with the function of ADJUST BATTERY.
Change the battery.
Wrong selection of SLIP PROFILE PARAMETERS.
Check the setting of these values in the hardware setting
parameters.