T
R
OUBLE PROBABLE CAUSE SUGGESTED REMEDY
A/
Fuse or circuit breaker has
blown.
A/
Check main and branch circuit
breakers.
B/
Loose wire connections to
the fan.
B/
Check line wire connections to
fan.
C/
Speed controller not in the
correct position.
C/
Check speed controllers position.
A/
Fan blades are not horizontal
to the ceiling.
A/
Retighten all screws on blades.
Do not
make any adjustments by
apply
ing pressure up or down on
blades.
B/
Blade screws are loose.
B/
Make
sure all screws are
tightened.
B/
Loose fan blades.
B/
Retighten all screws on fan.
C/
Ceiling fan not secured
against ceiling.
C/
Retighten all screws in the
hanging bracket.
D/
Incorrect speed controller.
D/
Change speed controller to the
one supplied with the unit.
Mechanical noise A/
Fan has not settled in fully.
A/
Allow at least 8 hours settling in
period.
Fan will not start
Fan wobbles
Fan sounds noisy
TROUBLE SHOOTING:
9