EasyManua.ls Logo

Helo Viki 6.0 - User Manual

Helo Viki 6.0
10 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
INSTALLATION AND OPERATING INSTRUCTIONS
4211-70 G
Rev. 3
5/9/14
R.D. LD
WARNING
SECTION 1: GENERAL INFORMATION
These heaters are ETL approved for permanent installations
and electrical connections. Built with splash proof construction,
the conducting parts are protected against water. All wiring
must be performed in accordance with national and local codes.
See Diagram 2 for wire and room size requirements. These
heaters are wall mounted.
Do not take a sauna if
using alcohol, drugs or
medications.
Pregnant women or
persons with poor
health should consult
their physician before
using any sauna.
Caution fire hazard: Do
not use the sauna room
for drying clothes,
bathing suits, etc. Do
not hang towels above
heater or place any
object other than the
rocks supplied on the
heater. If any darkening
of the wall around the
heater is noticed
discontinue sauna use
immediately.
Inspect sauna regularly
for required
maintenance to heater,
control and benches.
Replace wood surfaces
which show any signs
of deterioration.
The heater gets
extremely hot during
operation and should
not be touched or burns
may result.
Minors should be
adequately supervised
"
Viki
" Heater Sauna Series Models
4.5
,
6.0
,
8.0
(1720-45-02, 1720-60-02, 1720-80-
02)
w
ith "
SaunaLogic" Control
Read all instructions carefully before installation.
Please leave all instructions and warranty with the
owner.
WARNING
Prolonged exposure to elevated temperatures is capable of
inducing hyperthermia. Hyperthermia occurs when the internal
temperature of the body reaches several degrees above the
normal body temperature of 98.6°F. The symptoms of
hyperthermia include an increase in the normal temperature of
the body, dizziness, lethargy, drowsiness, and fainting. The
effects of the hyperthermia include failure to perceive heat,
failure to recognize the need to exit the room, unawareness of
impending hazard, fetal damage in pregnant women, physical
inability to exit the room and unconsciousness.
WARNING
The use of alcohol, drugs, or medication is capable of greatly
increasing the risk of fatal hyperthermia.
Control Box
CB PK-1
SaunaLogic Control

Other manuals for Helo Viki 6.0

Question and Answer IconNeed help?

Do you have a question about the Helo Viki 6.0 and is the answer not in the manual?

Summary

General Information and Safety

General Safety Warnings

Essential safety precautions regarding alcohol, drugs, health, fire hazards, and supervision.

Heater Installation

Mounting Heater and Control Box

Instructions for securely mounting the sauna heater and the PK-1 control box.

Placing Rocks

Guidelines for correctly placing sauna rocks for optimal heater performance and airflow.

Electrical Hook-Up

Procedures for connecting the heater to the electrical supply.

Temperature Sensor Installation

Steps for installing the temperature sensor for the control system.

Electrical and Sensor Setup

Electrical Hook-Up

Procedures for connecting the heater to the electrical supply.

Temperature Sensor Installation

Steps for installing the temperature sensor for the control system.

Sauna Operation Safety

General Operational Precautions

Precautions for fire sprinklers, water use, electrical shock, and heater rock packing.

Control System and Accessories

Heater Screen (Guard Rail)

Instructions for installing the heater screen to prevent burns.

SaunaLogic Control Installation

Guidance on installing and operating the SaunaLogic control unit.

Setting Time and Temperature

How to adjust the sauna's time and temperature settings.

Operational Safety Precautions

General Heater Safety

Safety notes on bench placement, clearances, wiring, outlets, and burn hazards.

Advanced Control Features

Programming Delay Start

Instructions for setting a delayed start for the sauna heater.

Light Installation

Information on installing compatible lighting kits with the control system.

High Limit Control

Explanation of the high limit control and how to reset it.

Sauna Usage and Room Requirements

How to Take a Sauna

Recommended procedure for taking a sauna session.

Warning Placard Placement

Guidance on where to mount warning and caution placards.

Sauna Room Construction Rules

Key rules for building a safe and compliant sauna room.

Sauna Environment Safety

Room Safety and Door Guidelines

Safety rules for room features, door operation, and lighting placement.

Operational Management

Ventilation Requirements

Specifications for proper sauna room ventilation.

Maintenance and Cleaning

Routine maintenance and cleaning procedures for the sauna and heater.

Troubleshooting and Support

Common error codes, troubleshooting steps, and contact information.

Overview

The "Viki" Heater Sauna Series Models (4.5, 6.0, 8.0, with product numbers 1720-45-02, 1720-60-02, and 1720-80-02 respectively) are ETL approved sauna heaters designed for permanent installations and electrical connections. These heaters are wall-mounted and feature splash-proof construction, protecting conducting parts from water. They are controlled by the "SaunaLogic" control system.

Function Description:

The "Viki" heater series provides heat for sauna rooms, allowing users to experience the benefits of a sauna bath. The SaunaLogic control system manages the heater's operation, including temperature and time settings, and offers a delay start function. The system also supports optional Spectra-Light kits for color therapy and interior/exterior white lighting.

Important Technical Specifications:

  • Heater Models and Power:

    • Viki 4.5 (1720-45-02): 4.5 KW
    • Viki 6.0 (1720-60-02): 6.0 KW
    • Viki 8.0 (1720-80-02): 8.0 KW
  • Minimum Room Size Requirements (Floor Area / Ceiling Height / Volume):

    • Viki 4.5: 12 sq. ft. / 73 1/2" / 100 Cu.Ft.
    • Viki 6.0: 21 sq. ft. / 73 1/2" / 175 Cu.Ft.
    • Viki 8.0: 31 sq. ft. / 73 1/2" / 250 Cu.Ft.
  • Maximum Room Size Requirements (Ceiling Height / Volume):

    • Viki 4.5: 96" / 210 Cu.Ft.
    • Viki 6.0: 96" / 310 Cu.Ft.
    • Viki 8.0: 96" / 425 Cu.Ft.
  • Electrical Specifications (per model, phase, VAC, AMPS):

    • Viki 4.5:
      • 1 Phase, 208 VAC: 21.6 AMPS (Wire Size: 2#10AWG+ GR for Power Supply to CB PK-1, 2#10AWG+ GR for CB PK-1 to Heater)
      • 1 Phase, 240 VAC: 18.8 AMPS (Wire Size: 2#10AWG+ GR for Power Supply to CB PK-1, 2#10AWG+ GR for CB PK-1 to Heater)
      • 3 Phase, 208 VAC: 12.5 AMPS (Wire Size: 3#12AWG+ GR for Power Supply to CB PK-1, 3#12AWG+ GR for CB PK-1 to Heater)
      • 3 Phase, 240 VAC: 10.8 AMPS (Wire Size: 3#12AWG+ GR for Power Supply to CB PK-1, 3#12AWG+ GR for CB PK-1 to Heater)
    • Viki 6.0:
      • 1 Phase, 208 VAC: 28.8 AMPS (Wire Size: 2#8AWG+ GR for Power Supply to CB PK-1, 2#8AWG+ GR for CB PK-1 to Heater)
      • 1 Phase, 240 VAC: 25 AMPS (Wire Size: 2#10AWG+ GR for Power Supply to CB PK-1, 2#10AWG+ GR for CB PK-1 to Heater)
      • 3 Phase, 208 VAC: 16.7 AMPS (Wire Size: 3#12AWG+ GR for Power Supply to CB PK-1, 3#12AWG+ GR for CB PK-1 to Heater)
      • 3 Phase, 240 VAC: 14.4 AMPS (Wire Size: 3#12AWG+ GR for Power Supply to CB PK-1, 3#12AWG+ GR for CB PK-1 to Heater)
    • Viki 8.0:
      • 1 Phase, 208 VAC: 38.5 AMPS (Wire Size: 2#8AWG+ GR for Power Supply to CB PK-1, 2#8AWG+ GR for CB PK-1 to Heater)
      • 1 Phase, 240 VAC: 33.3 AMPS (Wire Size: 2#8AWG+ GR for Power Supply to CB PK-1, 2#8AWG+ GR for CB PK-1 to Heater)
      • 3 Phase, 208 VAC: 22.2 AMPS (Wire Size: 3#10AWG+ GR for Power Supply to CB PK-1, 3#10AWG+ GR for CB PK-1 to Heater)
      • 3 Phase, 240 VAC: 19.2 AMPS (Wire Size: 3#10AWG+ GR for Power Supply to CB PK-1, 3#10AWG+ GR for CB PK-1 to Heater)
  • Minimum Clearances to Combustible Material:

    • "A" (Side clearance): Viki 4.5 (3"), Viki 6.0 (4"), Viki 8.0 (5")
    • "B" (Front clearance): Viki 4.5 (4"), Viki 6.0 (5"), Viki 8.0 (6")
    • "C" (Upper bench clearance): Viki 4.5 (4"), Viki 6.0 (5"), Viki 8.0 (6")
    • "D" (Guard rail clearance): 12 1/4" for all models
    • "K" (Corner clearance): 26 1/2" for all models
    • Minimum ceiling spacing: 73 1/2"
    • Minimum spacing from control box (CB PK-1) to heater: 18"
    • Maximum spacing from control box (CB PK-1) to heater: 10"
    • Sensor location: 2" down from ceiling, directly above heater.
  • Ventilation: Air should be changed about 6 times an hour. Minimum vent size (V) in square inches is determined by the floor area (R) in square feet:

    • For R < 31: V > 9.3
    • For R > 31: V > 0.3R

Usage Features:

  • SaunaLogic Control: The external control unit allows users to set the desired temperature (125°F to 194°F / 90°C max) and bath time (0 to 60 minutes).
  • ON/OFF Button: Activates the heater and displays room temperature.
  • Temperature Adjustment: "+" and "-" buttons to increase or decrease temperature.
  • Time Adjustment: "+" and "-" buttons to increase or decrease bath time.
  • Delay Start Function: Allows programming a delayed start for the sauna, with a flashing semi-colon on the display indicating delay mode. The delay can be set for up to 8 hours and 30 minutes.
  • High Limit Control: A built-in safety feature that automatically turns off the heater if the sauna room temperature rises to an abnormally high level. The control displays "HL" when tripped. To reset, the heater must cool down, and the ON/OFF button must be pressed.
  • Sauna Rocks: Specifically chosen rocks are supplied for optimal heater performance. They must fully cover the heating elements and be placed loosely to allow air circulation.
  • Heater Guard Rail: A wooden guard rail is required to prevent accidental contact with the hot heater.
  • Warning Placards: "CAUTION" and "WARNING" placards are provided and must be mounted inside the sauna room as per instructions to inform users of potential risks (e.g., overheating, fire hazard, health warnings).
  • Sauna Door Requirements: The sauna door must open outwards and not have a permanent locking or latch system. Acceptable fittings include magnetic, friction, spring, or gravity-loaded closures.
  • Lighting Control: The SaunaLogic control is designed to operate Spectra-Light kits (accessory) which include internal color therapy, interior white, and exterior white lights. The control has three buttons for managing these light circuits.

Maintenance Features:

  • Regular Cleaning: The sauna room, including benches and floor, should be kept clean and odor-free. Towels or mats should always be used on benches and the floor to absorb perspiration.
  • Air Out Sauna: Keep the door and vents open when the sauna is not in use to air it out.
  • Weekly Wash Down: For daily use saunas, a weekly wash down is recommended to keep them clean and fresh. Duckboards should be removed, the floor mopped and dried, and the duckboards thoroughly scrubbed and dried.
  • Heater Cleaning: The sauna heater should be wiped down occasionally with a damp cloth to remove lint and dust.
  • Rock Maintenance: Sauna rocks should be removed once a year for cleaning, and any small or crumbled rocks should be replaced.
  • Perspiration Stain Removal: Use soap or detergent in warm water with a scrub brush. Heavily soiled surfaces may require sanding.
  • Bench Inspection: Benches and supporting structures must be inspected annually for deterioration due to age, dry rot, or abuse. Any damaged boards should be replaced immediately to prevent injury.
  • Troubleshooting Display Codes:
    • "SN": Indicates no sensor is connected. Refer to Section 5 for sensor installation.
    • "HL": Indicates the high limit is open and the heater is too warm. Refer to Section 9 for high limit information.
  • Technical Support: For troubleshooting or service questions, contact 1-888-780-4427 or email techsupport@saunatec.com. Model and type numbers should be available when contacting support.