7
EN
Descaling
The orange indicator light (6) will be illuminat-
ed when the boiler gets too hot and needs to be
cleaned and/or descaled.
This appliance should be cleaned and descaled
frequently. To keep this appliance in optimum
condition and to ensure its operation, it is cru-
cial that you descale the appliance on a regular
basis. Depending on the hardness of the water
and the frequency of use, you need to repeat the
following procedure regularly.
To descale use a descaling agent that is suitable
for coffee makers. You can also use pure lemon
juice, citric acid or cleaning vinegar as a de-scal-
ing agent. To ensure the proper mixture, read
the instructions supplied with the agent. For
pure lemon juice or cleaning vinegar the general
mixture applies of 1/3 cleaning vinegar or lemon
juice to 2/3 water.
1. Pour the solution in the boiler to maximum the
“MAX” level.
2. Wait to allow the solution to loosen the build-
up.
3. Rub lightly and gently with a brush with soft
bristles.
4. Drain off the dirty water.
5. Repeat steps 1~4 until build-up has been re-
moved.
6. Use a dry cloth to wipe the solution away.
7. When you drain off dirty water, leave the tap
open and rinse the boiler with clean water till
taste and smell are completely gone.
8. Now you can use the boiler again.
Note: Warranty is void if failure to de-scale reg-
ularly leads to reduced functioning or failure of
the appliance.
Troubleshooting
If the appliance does not function properly, please check the below table for the solution. If you are
still unable to solve the problem, please contact the supplier/service provider.
Defect Problem Cause Possible solution
Appliance does not
work at all.
Neither green on/
off light nor indicator
light is illuminated.
No mains power.
Check the electrical
connections.
Boiler switches off
automatically.
The orange light is
illuminated.
Boiler has exceeded
maximum safety
limits.
Once it has cooled off,
the boiler will switch
on again automati-
cally.
Boiler does not reach
the selected temper-
ature.
Green light is not
illuminated.
Thermostat does not
work.
Contact your supplier.
Heating element does
not work.