  • T
    Travis HenryAug 13, 2025
    What to do if my Henkelman Industrial Equipment doesn’t function?
    • A
      Ashley FreemanAug 13, 2025
      If your Henkelman Industrial Equipment isn't functioning (no power light or display), first, ensure the plug is properly connected. If it is, check and replace any burned fuses from the main power supply. Then, check and reset the automatic fuse in the electrical cabinet. Finally, verify that the main switch on the backside of the machine is switched on.
  • R
    Raymond PadillaAug 17, 2025
    What to do if the display shows “E1” on my Henkelman Industrial Equipment?
    • C
      Crystal HartAug 17, 2025
      If the display of your Henkelman Industrial Equipment shows “E1”, it could be due to an insufficient water level. Add water to the recommended level, keeping it max. 10 cm under the edge, preferably using un-chalked water. Alternatively, there might be a disconnection or malfunction in the connection cable, the temperature sensor (P1), or the floating device (S5). Check the connections and the function of these elements.
  • D
    Daniel FosterAug 21, 2025
    Why isn’t my Henkelman Industrial Equipment heating up?
    • M
      Michael SmithAug 21, 2025
      If your Henkelman Industrial Equipment isn't heating up but the power light is on, it might be due to an insufficient water level. Add water to the recommended level, ensuring it's no more than 10 cm under the edge, and preferably using un-chalked water. It could also be that the temperature value is too low, so try increasing the temperature. If neither of these resolves the issue, there may be a temperature control malfunction, which requires checking the temperature control.
  • A
    amy38Aug 25, 2025
    What to do if the platform is not rising in my Henkelman Industrial Equipment?
    • R
      Renee HarrisAug 25, 2025
      If the platform of your Henkelman Industrial Equipment is not rising, the total weight of the products might be too much. Switch off the machine, let the water cool down or drain it, remove some of the product, and start again. Alternatively, the thermal overload could be activated, so check the setting. It may also be due to a time relay malfunction, so check the time relay. Finally, ensure there is a sufficient amount of oil by checking the oil level.
  • K
    Kimberly JacobsAug 28, 2025
    What to do if the platform is not going down in my Henkelman Industrial Equipment?
    • E
      Erik HarrisAug 28, 2025
      If the platform of your Henkelman Industrial Equipment is not going down, the rotating direction of the pump might be wrong; interchange two phases. It could also be that the start switch is disconnected or broken, so check the start switch. Another possibility is that the thermal overload pump is activated; check the setting. Note that the thermal overload will activate automatically after cooling down.
  • L
    Lisa McdanielSep 1, 2025
    Why is my Henkelman Industrial Equipment heating up without water?
    • C
      Christopher RoblesSep 1, 2025
      If your Henkelman Industrial Equipment is heating up despite the absence of water, the floating device might be blocked in the top position. Check the floating device and clean it if necessary.
  • J
    Joseph BellSep 4, 2025
    Why does the platform only go down when I push the start button on my Henkelman Industrial Equipment?
    • J
      Jordan HunterSep 5, 2025
      If the platform of your Henkelman Industrial Equipment only goes down when the start button is pushed, the micro switch (S4) might be malfunctioning. Check the micro switch (S4).
  • J
    Julie WilliamsSep 8, 2025
    Why is the pump running after the cycle is complete in my Henkelman Industrial Equipment?
    • C
      Crystal PalmerSep 9, 2025
      If the pump is running after completing the total cycle in your Henkelman Industrial Equipment, the micro switch (S4) may have a short cut; check its proper function and correct position. Alternatively, the start button (S3) might have a short cut; check its proper function and correct position as well.