EasyManua.ls Logo

HERF HERF-1200 - Technical Data; DC Input; AC Output; Efficiency, Safety and Protection

Default Icon
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
202207V1.1
21
info@estarpower.com
www.estarpower.com
7.Technical Data
7.1DC Input
7.2AC Output
7.3Efficiency, Safety and Protection
Model
HERF-1200
HERF-1600
HERF-1800
Commonly used module power (W)
Up to 420+
(Single panel)
Up to 540+
(Single panel)
Up to 670+
(Single panel)
Peak power MPPT voltage range (V)
16~48
16~48
16~48
Start-up voltage (V)
22
22
22
Operating voltage range (V)
16~60
16~60
16~60
Maximum input voltage (V)
60
60
60
Maximum input current (A)
4*13
4*13.5
4*14
Maximum input short circuit current (A)
4*20
4*20
4*20
Model
HERF-1200
HERF-1600
HERF-1800
Rated output power (W)
1200
1600
1800
Rated output current (A)
5.22
6.96
7.83
Nominal output voltage/range (V)
230/180-270
230/180-270
230/180-270
Nominal frequency/range (Hz)
45-55 (under 50Hz @ 220V & 230V)
Power factor
>0.99
Output current harmonic distortion
<3%
<3%
<3%
Maximum units per branch
6
4
4
Model
HERF-1200
HERF-1600
HERF-1800
CEC peak efficiency
96.50%
96.50%
96.50%
Nominal MPPT efficiency
99.50%
99.50%
99.50%
Night time power consumption (mW)
<50
<50
<50