EasyManuals Logo

Hessaire HTH01 User Manual

Default Icon
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
HTH01 Instruction 030923 www.hessaire.com
Control Operation
Installation
WARNING: High Voltage can cause serious injury or death.
Control must be installed by a qualified electrician. Turn off
all power before starting installation.
CAUTION: Follow all local building / electrical codes
CAUTION: Do not attempt to repair or service control.
Components are not serviceable.
WARNING: Failure to follow instructions and warnings may
lead to property damage or personal injury.
Troubleshooting
Mounting Control To Wall
Control is designed to mount in an electrical box.(sold separately)
WARNING: Make sure all power is off.
Locate position on wall in area that is convenient to access and
control your evaporative cooler.
Use qualified electrician to install thermostat, run proper sized
wiring and correctly make all connections.
Once all connections are properly made and control is secured
to electrical box, power can be turned back on.
MODEL: HTH01
WiFi Evaporative Cooler Line-Voltage Thermostat
Press and hold MODE button for 2 seconds to select Auto MODE. Use the
temperature arrow setting buttons to set the desired temperature. There will
be a 2 minute “Pre-Wet” cycle which turns only the pump on to wet the media
before the fan turns on. If the room temperature is 4°F higher than the set
temperature, the fan will start on high(Hi) speed. When the room temperature
drops within 2°F of the set temperature, the fan will enter low(Lo) speed until
the set temperature is reached. Both the fan and pump will shut off at this
point. Pressing the fan speed button can also manually set the fan speed in
Auto MODE. The pump cannot be independently turned off in Auto MODE.
Control Functions
Automatic Mode:
Manual Mode:
Press and hold MODE button for 2 seconds to select Manual MODE. In this
mode, the pump can be turned on or off independently. The fan speed can
also be selected independently. The thermostat will not shut off the function
of the cooler in Manual MODE.
Timer:
The timer function is used to turn off the cooler after a set period of time. To
operate the timer function, push the “clock” button to enter the timer setting.
The humidity display box will switch to show the timer display. Use the up
and down arrows to set the desired delay time.
AC115V / 230V 60HZ
Electrical Ratings
INPUT OUTPUT
WHITE/COM
(L2)
RED POWER
(L1)
BLACK:
FAN HIGH
YELLOW:
FAN LOW
BLUE:
PUMP
115Vac: 60Hz, 15.2A
115Vac: 60Hz,
14.0A, 1Hp
115Vac: 60Hz,
9.0A, 1/3Hp
115Vac: 60Hz,
1.2A, 1/40Hp
230Vac: 60Hz, 7.8A
230Vac: 60Hz,
7.0A, 1Hp
230Vac: 60Hz,
4.5A, 1/3Hp
230Vac: 60Hz,
0.8A, 1/40Hp
Issue Possible Cause Action
Cooler won't turn
on / display off
Incorrect wire connections Check connections
Circuit breaker off Reset breaker
Control faulty Replace control
Fan / pump not
turning on
Bad wire connection Check connections
Motor failed Replace motor
Pump failed Replace pump
Control faulty Replace control
(WiFi Set Up On Back)
WiFi Control
Auto Set Temperature
Or Override With
Manual Setting
2-Speed Standard
Cooler Motor
Up To 1HP
Pump Controlled
Independently
Automatically
Pre-Wet In
“Auto” Mode
Large, Easy
To Read
Temperature
Dispays
Displays Relative
Humidity In Room
When Timer Is
Not In Use. 12 Hr
Delay Timer Can
Be Set In Hour
Increments
Features
Volts: 115 / 230
Operates all standard evaporative
coolers
Use with standard 2-speed cooler
motors up to 1 HP
Large, easy to read digital displays
Relative Humidity % readout
Delayed off timer up to 12 hours
Fits in single gang wall box

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hessaire HTH01 and is the answer not in the manual?

Hessaire HTH01 Specifications

General IconGeneral
BrandHessaire
ModelHTH01
CategoryThermostat
LanguageEnglish