Operation
The fan is rated for connection to single-phase AC220-240 V / 50/60 Hz power mains. The fan is
designed for continuous operation always connected to mains power. Air motion direction in the
system must match the pointer on the fan casing. Ingress protection rating IPX4.
Maintenance
Fan maintenance is to be performed only aer the fan is disconnected from the mains power suppy.
Maintenance means periodic cleaning of the surface of dust and dirt.
All surfaces should be cleaned with diluted detergent, i.e. washing up liquid, and a so cloth.
Scourers and scouring agents should not be used, as these may cause damage to the surface of the
product.
Avoid water dripping on the electric components. Wipe the surfaces dry aer cleaning.
Technical Information
Power Input: 220-240V, 50/60Hz
Maximum Ventilation Volume: 210 m3/hr (±5%) / 58.333 Litres Per Second
Power Consumption: 25W + 3W LED Lamp (32600, 33800, 32700 & 33700 only)
Decibel: 32dB
Dimensions: Ø14 x D7.3cm