INSTRUCTION MANUAL
- 59 -
10. TROUBLESHOOTING
·Please check the following points before calling for repairs or service.
·If the following remedies do not fix the problem, turn off the power switch and consult a qualified technician or the
place of purchase.
DANGER
Wait at least 5 minutes after turning off the power switch and disconnecting the power cord from the wall outlet
before opening the face plate of the control box. Touching areas where high voltages are present can result in severe
injury.
CAUTION
Turn off the power switch and disconnect the power cord before carrying out troubleshooting.
The machine may operate if the treadle is depressed by mistake, which could result in injury.
Items with a “*”in the “Page” column should only be checked by a qualified technician.
Problem Possible cause Page
1
Upper thread is not tight
· Is the upper thread tension too weak, or is the lower thread tension too
strong
Adjust the upper thread tension or lower thread tension.
· Is the needle and feed timing correct
Advance the needle timing.
44
55
2
Lower thread is not tight
· Is the lower thread tension too weak, or is the upper thread tension too
strong
Adjust the lower thread tension or upper thread tension.
44
3
Loops appear in seam
· Is the thread path not smooth enough
Use a file with a fine grain or sandpaper to polish smooth the
thread path.
· Is the bobbin not turning smoothly
Pull out the lower thread to check that there is no slackness in the
thread tension, or replace the bobbin or bobbin case.
4
Skipped stitches occur
while sewing
· Is the needle tip bentIs the needle tip blunt
If the needle tip is bent or broken, replace the needle.
· Is the needle properly in stalled
If it is incorrect, install the needle correctly.
· Is the machine properly threaded
If it is in correct, thread the thread correctly.
· Is the presser foot pressure too weak
Adjust the presser foot pressure.
· Is the needle too thin
Replace the needle with a needle that is one rank thicker.
· Is the presser foot too thin
Adjust the height of the presser foot.
· Is the thread take-up spring too weak
Adjust the tension of the thread take-up spring.
· Is the needle and rotary hook timing correct?
Adjust the height of the needle bar.
Adjust the clearance between the needle and the tip of the
rotary hook.
40
40
42
45
54
58

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hikari H9199 and is the answer not in the manual?

Hikari H9199 Specifications

General IconGeneral
BrandHikari
ModelH9199
CategorySewing Machine
LanguageEnglish

Related product manuals