2. You can editing the following parameters:
Door Magnetic: The Door Magnetic is in the status of Remain Closed (excluding special
conditions).
Exit Button Type: The Exit Button Type is in the status of Remain Open (excluding special
conditions).
Door Locked Time: After swiping the normal card and relay action, the timer for locking the
door starts working.
Door Open Duration by Card for Disabled Person: The door magnetic can be enabled with
appropriate delay after disabled person swipes the card.
Door Open Timeout Alarm: The alarm can be triggered if the door has not been close
Enable Locking Door when Door Closed: The door can be locked once it is closed even if the
Door Locked Time is not reached.
Duress Code: The door can open by inputting the duress code when there is duress. At the
same time, the client can report the duress event.
Super Password: The specific person can open the door by inputting the super password.
Dismiss Code: Input the dismiss code to stop the buzzer of the card reader.
Notes:
The duress code, Super password, and dismiss code should be different.
The duress code, super password, and the dismiss code should be different from the
authentication password.
The duress code, super password, and the dismiss code should contain 4 to 8 numerics.
3. Click Save button to save parameters.
Card Reader Parameters
Steps:
1. In the device list on the left, click to expand the door, select the card reader name and you
can edit the card reader parameters on the right.

Table of Contents

Other manuals for HIKVISION DS-K2802

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION DS-K2802 and is the answer not in the manual?

HIKVISION DS-K2802 Specifications

General IconGeneral
Product typeAccess controller
CertificationCE, FCC
CompatibilityWiegand
Mounting typeWall
Product colorBlack
Brand compatibilityHikvision
Operating temperature (T-T)-20 - 65 °C
Quantity per pack1 pc(s)
Weight and Dimensions IconWeight and Dimensions
Depth285 mm
Width237 mm
Height69 mm

Related product manuals