2. Short press down the coding buon on the boom of the first detector, the red LED flashes slowly, approximately once every one second. Release the buon
then. Noce pressing the coding buon again will end the coding process.
3. Turn on the power switch on the boom of the second detector.
4. Short press down the coding buon on the boom of the second detector, the red LED flashes slowly, approximately once every one second. Then release
the buon.
5. wait and see…
At this me, the two detectors are in the coding mode. The period of coding is about 60 seconds.
If two green LEDs of the detectors are illuminated at the same me, no flashing, which indicates that two detectors have built a new wireless interconnecon, the
coding is successful. Otherwise, aer 60 seconds, two detectors will exit the coding mode automacally, please do it again. Please noce repeated press of coding
buon will also end the coding process.
6. To connect another smoke detector. Repeat above steps. First, choose the new smoke alarm you want to add. Then choose a smoke alarm already interconnect-
ed. The new smoke alarm shall join the exisng network. Repeat the above steps for other interconnected smoke alarms (up to 12).
7. Once all smoke alarms are interconnected, press the Test/Hush on each smoke alarm, and check the smoke alarm sounder operates on all interconnected smoke
alarms.
8. Check that the red LED adjacent to the Test/Hush buon operates only on the smoke alarm being tested.
Smoke detectors should be interconnected within only one family residence. Otherwise, you might encounter nuisance alarms when a smoke detector is
operated or tested in another residence.