TECHNICAL & SERVICE MANUAL V1.1
—MULTI-SPLIT TYPE AIR CONDITIONERS
R410A
Refrigerant
R410A
Refrigerant
R410A
Refrigerant
R32
Refrigerant

Table of Contents

Questions and Answers

  • W
    william13Aug 12, 2025
    Why my Hisense AMW5-42U4RTA can not start up?
    • T
      Tammy ThompsonAug 12, 2025
      If your Hisense Air Conditioner isn't starting, several factors could be at play. First, check the power supply circuit to ensure it's functioning correctly. A tripped breaker or blown fuse could also be the culprit. Also, measure the insulation resistance to ground to check for any leakage. Low power voltage can also prevent startup. Verify the remote controller settings and try setting it again, and replace the batteries in the remote controller.
  • U
    ujohnsonAug 16, 2025
    What to do if my Hisense Air Conditioner has poor cooling/heating?
    • K
      Kimberly HillAug 16, 2025
      If your Hisense Air Conditioner is not cooling or heating effectively, start by cleaning the heat exchanger of the outdoor unit, such as the condenser. Ensure there are no heating devices indoors that might be affecting the temperature. Maintain good air tightness indoors by minimizing how often people enter and exit. Check for and remove any obstructions blocking the outdoor heat exchanger. Finally, double-check and reset the temperature to the desired setting.
  • C
    Christopher PierceAug 20, 2025
    Why does the compressor of my Hisense AMW5-42U4RTA start and stop frequently?
    • D
      Dale HawkinsAug 20, 2025
      If your Hisense Air Conditioner's compressor starts and stops frequently, it's likely that the air inlet or outlet is blocked. Remove any obstacles to ensure proper airflow.
  • D
    David DavisAug 23, 2025
    How to fix water leakage in Hisense AMW5-42U4RTA Air Conditioner?
    • S
      Sarah CherryAug 23, 2025
      If your Hisense Air Conditioner is leaking water, the drainage pipe may be blocked or broken, in this case, change drainage pipe. Alternatively, the wrap of the refrigerant pipe joint might not be completely sealed; re-wrap it tightly.
  • W
    wvaughnAug 27, 2025
    Why is my Hisense AMW5-42U4RTA Air Conditioner not cooling/heating properly?
    • X
      xstewartAug 27, 2025
      There could be several reasons why your Hisense Air Conditioner isn't cooling or heating effectively. It might be due to a dirty outdoor heat exchanger (like the condenser), heating devices operating indoors, insufficient air tightness from frequent entry/exit, a blocked outdoor heat exchanger, or an incorrect temperature setting. To resolve this, try cleaning the outdoor unit's heat exchanger, removing any indoor heating devices, maintaining better air tightness, clearing any obstructions from the outdoor heat exchanger, and double-checking your temperature settings.
  • J
    Jonathan VillarrealAug 31, 2025
    How to fix water leakage from Hisense AMW5-42U4RTA Air Conditioner?
    • T
      Timothy McintoshAug 31, 2025
      Water leakage from your Hisense Air Conditioner could be caused by a blocked or broken drainage pipe, or an improperly sealed refrigerant pipe joint. Try changing the drainage pipe. Also, re-wrap the refrigerant pipe joint to ensure it is tightly sealed.
  • C
    Casey AllisonSep 3, 2025
    What to do if Hisense Air Conditioner can not start up?
    • L
      Lisa WrightSep 4, 2025
      If your Hisense Air Conditioner won't start, the issue might stem from a power supply failure, a tripped breaker or blown fuse, low power voltage, incorrect remote controller settings, or a dead remote battery. You should inspect the power supply circuit, measure the insulation resistance to check for leakage, and look for defective contacts or current leaks in the power supply. Also, verify and reset the remote controller, and replace the batteries if needed.
  • T
    Tina JacobsSep 8, 2025
    Why does the compressor in my Hisense AMW5-42U4RTA Air Conditioner start and stop frequently?
    • H
      Helen SmithSep 8, 2025
      If the compressor in your Hisense Air Conditioner is starting and stopping frequently, it's possible that the air inlet or outlet is blocked. Remove any obstacles that may be causing the blockage.

Summary

MULTI-SPLIT TYPE AIR CONDITIONERS

SAFETY SUMMARY

Essential safety information and precautions for installation, service, and operation.

SPECIAL PRECAUTIONS

Crucial safety steps for wiring and handling the units to prevent injury.

1. GENERAL

1.4 Unit Installation

Guidelines for connecting multiple indoor units to a single outdoor unit and combination rates.

3. ELECTRICAL DATA

4. CAPACITIES AND SELECTION DATA

7. REFRIGERANT CYCLE

9. WIRING DIAGRAM

9.1 Electrical Wiring Diagrams

Electrical schematics for outdoor units of various models (18K to 42K).

9.3 Common Wiring and Electrical Data

Common wiring configurations, electrical specifications, and recommended wire sizes.

10. FIELD SETTING

11. PIPING WORK AND REFRIGERANT CHARGE

12. INSTALLATION TOOLS AND FLOW CHART

13. CONTROL MODE

14. SENSOR PARAMETER

Sensor Parameter Table

Table showing resistance values for outdoor compressor discharge temperature sensors at various temperatures.

15. TROUBLESHOOTING

15.1 Trouble Guide

Guide to common malfunctions, their possible reasons, and recommended solutions.

15.2 Fault Codes

Detailed tables listing fault codes, descriptions, possible reasons, and troubleshooting steps.

17. DISASSEMBLY PROCEDURE

SPLIT TYPE AIR CONDITIONER SERVICE MANUAL Version: 1.0

1. Safety Considerations

Vital safety information and precautions for installation and service personnel.

IMPORTANT!

Critical safety instructions to be read before starting any work.

Special Precautions

Crucial safety steps for wiring and handling the units to prevent injury.

3. Installation Instruction

Guidelines for selecting proper installation locations and conditions for indoor units.

3-1. Installation Place and Condition

Detailed criteria for choosing the optimal location for indoor unit installation.

3-2. Electric Wiring Diagram

Electrical wiring diagram for the indoor unit, showing component connections.

4. Electrical Characteristics

Information on indoor unit print circuit boards and their model numbers.