EasyManua.ls Logo

Hisense AUD-60UX4RHH4 User Manual

Hisense AUD-60UX4RHH4
204 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
TECHNICAL & SERVICEMANUAL V3.0
—DC-INVERTER AIR CONDITIONERS
R410A
Refrigerant
R410A
Refrigerant
R410A
Refrigerant
R32
Refrigerant
Question and Answer IconNeed help?

Do you have a question about the Hisense AUD-60UX4RHH4 and is the answer not in the manual?

Hisense AUD-60UX4RHH4 Specifications

General IconGeneral
BrandHisense
ModelAUD-60UX4RHH4
CategoryAir Conditioner
LanguageEnglish

Summary

1. General Product Information

2. Specifications by Unit Type

Duct Type Specifications

Detailed technical specifications for Duct type air conditioners.

Cassette Type Specifications

Detailed technical specifications for Cassette type air conditioners.

Ceiling & Floor Type Specifications

Detailed technical specifications for Ceiling & Floor type air conditioners.

Console Type Specifications

Detailed technical specifications for Console type air conditioners.

5. Capacities and Selection Data

Capacity Characteristic Charts by Type

Cooling and heating capacity data for Duct, Cassette, Ceiling & Floor, and Console types.

Piping Length Correction Factors

Tables showing correction factors based on piping length and height difference.

6. Sound Pressure Data

8. ESP Charts for Duct Type Units

Duct Type ESP Charts by Capacity

External Static Pressure charts for Duct type units at different capacities.

9. Refrigerant Cycle Diagrams

11. Wiring Diagrams and Common Wiring

Indoor Unit Electrical Wiring Diagrams

Wiring diagrams for various indoor unit types (Duct, Cassette, Ceiling & Floor, Console).

Indoor Unit Control Board Layouts

Visual identification of components on indoor unit control boards.

Common Wiring and Wire Size Recommendations

Guidelines for wiring, ELB, and wire size selection.

12. Field Setting Procedures

13. Piping Work and Refrigerant Charge

Maximum Piping Length and Height Difference

Guidelines for maximum pipe length, height difference, and additional refrigerant.

Oil Bend and Air Tight Test Procedures

Procedures for installing oil bends and performing air tight tests.

14. Control Mode Operations

16. Troubleshooting Guides

Fault Code Indication Methods

Explains how fault codes are displayed via remote controller, panel LEDs, and outdoor unit LEDs.

Fault Code Reference Tables

Lists fault codes, causes, and recommended solutions for outdoor and indoor units.

17. Component Checking Procedures

Refrigerant System Checking Procedure

Step-by-step guide and flowcharts for checking the refrigerant system.

Component Checking and Testing

Procedures for checking indoor unit fan motors, compressors, fuses, and capacitors.

18. Disassembly and Assembly Instructions

19. Control Logic Descriptions

Evaporator Low-Temperature Protection Logic

Conditions and actions for evaporator low-temperature protection (T2 protection).

Condenser High-Temperature Protection Logic

Conditions and actions for condenser high-temperature protection (T3 protection).

Related product manuals