Technical Specification
Power Supply “Lifetime Power” Lithium battery (10 years)
Battery Capacity 1600 mAh
RF Frequency 868Mhz
Operating Temperature 0
o
C to 40
o
C (Cat 3)
Humidity 15% - 95% (Non Condensing)
Receiver Category Cat 2
EMC Performance EN 301 489-1, EN 301 489-3
Safety Testing EN 60065
RF Power +7dBm
Number of RF Alarms 20 per Home Group
inc. control unit
Control Unit
functionality
Yellow LED
Low Battery /
Fault Alarm
Red LED
CO Warning
Test / Silence
Red LED
Fire Warning
Test / Silence
Home
Group
Button
Function
Test
Locate
Silence
F
ire Indicator
Low Battery Indicator
Memory
Description
All of the Alarms can be tested
from a centralised location
This will silence the Home Group
Indicates that a Fire Alarm has been
activated
This will silence all the Alarms in the
system except the one sensing Fire
Indicates that the Control Unit battery
has reached the end of its life
Hispec
Home Group
The memory feature allows the Control
Unit to stay connected with
ed alarms
Test / Silence Button
Locate Button
Power on and off switch
Front View of Controller Rear View of Controller
Home Grouping
Please read through all of the steps thoroughly before installation.
It is essential to “Home Group” the control switch to all of the alarms in
the system, to ensure they will not communicate with any other
nearby systems. Failure to “Home Group” the system will prevent it
from operating correctly.
**Do this BEFORE you install any of the devices!**
Setting up the Home Group
1. Turn the power on with the switch on the back of the Control
Unit.
2. Turn on all alarms to be installed in the system by sliding them
onto their baseplates until they click into place.
3. Press and hold the “Home Group” button (H CODE) on the
back of the Control Unit until the Red LED lights up on the front
as pictured below, then release. Now the Control Unit is in
“Home Grouping” mode.
Note: The “Home Grouping” mode on the controller will be active
for 2 minutes 30 seconds. After this period, it will
turn off automatically.
Red LEDs
light up
CO
TEST / SILENCE
LOCATE
Use a screw driver
to press and hold
the H.Code at
the back of controller
/ SILENCE
H.CODE
ON POWER OFF
H.CODE
ON
POWER
OFF
HSSA/CU/RF10-PRO
RF-PRO Control Unit Instruction Manual
4. “Home Group” all of the alarms in the system.
Mains powered alarms: press the small rectangular pairing button
on the side of the alarm baseplate TWICE. A red LED next to this
button will flash 5 times.
Battery smoke/heat: press the small black pairing button on the
back of the alarm TWICE. The red LED on the front will flash five
times.
Battery CO: press the TEST/SILENCE button slowly so red and
green LEDs flash once each time. The red LED will then flash 3
times.
This alarm is now in the Home Group.
5.Repeat Step 4 for each additional alarm. Ensure the Red LED
stays lit on the Control Unit throughout - if it goes off before you
have finished, repeat Step 3 and continue Step 4 with any alarms
not yet joined to the Home Group.
6.Now all of the devices are joined in the Home Group, they can be
installed.
7.For details on individual alarm devices, consult the instruction
manuals enclosed with them.
Note: The Control Unit and all of the connected Home Group
alarms have a memory function. When they are disconnected from
their power supply or turned off (i.e. for installation) they will remain
joined to the Home Group.
Range
All the RF-PRO Models have a maximum wireless connection
range of upto 80m in an open outdoor space and 30m indoors.
The Hispec RF-PRO Control Unit can link to and control
up to 19 alarms in the Hispec RF-PRO range, consisting
of smoke alarms, heat alarms, and Carbon Monoxide
(CO) alarms.