SinCos Encoder Min Max Values are heading
towards a voltage rail or converging together.
A fault ride through event has been encountered,
but operation is allowed to continue although the
system may be derated
The open loop VF induction motor software has
detected a pulled-out condition, it will
automatically attempt to restart.
Stator resistance thermal compensation has
failed due to the estimated value being too
different from the configured value
Encoder PLL Deactivated Warning
Encoder PLL has turned off due to poor tracking
Vehicle is operating in reduced power mode as
some CAN messages are not being received
(Renault only)
Scheduler stack overflow warning
This warning is set if any task has between 10%
and 20% of its stack free.
Internal supply out of range
warning
An internal logic supply rail has gone out of
range
CANopen anon EMCY level 1
EMCY message received from non-Sevcon node
and anonymous EMCY level (0x2830,0) is set to
1.
Vehicle service next due time (0x2850,5) has
expired. If supported Service driveability profile
(0x2925) will activate.
Valid direction selected with operator not seated
or operator is not seated for a user configurable
time in drive.
Both the forward and reverse switches have
been active simultaneously for greater than 200
ms.
FS1 active for user configurable delay
(0x2914,2) without a direction selected.
Any drive switch active at power up.
FS1 active after a direction change and FS1
recycle function enabled (0x2914,1 bit 1)
Inch switch active along with any drive switch
active (excluding inch switches), seat switch
indicating operator present or handbrake switch
active.
Scissor lift platform raised and tilted
Scissor lift pothole protection active