EasyManua.ls Logo

Hitachi 88-02-0 Series - Chapter 2: System Controller; CBL Controller Chassis; CBL Controller Front Panel Bezel Leds

Hitachi 88-02-0 Series
135 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 2: System controller
The storage systems are equipped with dual controllers for communicating with a data
host.
Each controller includes the following internal components such as a processor, dual in-
line cache memory modules (DIMMs), cache ash memory (CFM), battery, and fans. The
controller has an Ethernet connection for out-of-band management using Hitachi Device
Manager - Storage Navigator. If the data path through one controller fails, all drives
remain available to data hosts using a redundant data path through the other controller.
The controller is equipped with LED indicators for monitoring its operating conditions
and notifying possible component replacement.
CBL controller chassis
The controller chassis houses controllers, backup fan modules, and power supplies. The
chassis also includes specic functional LEDs located on the front and rear of controller
to provide its operating status.
The following table lists the controller board specications.
Component VSP G900
Chassis (4U) DW850-CBL
Controller board DW-F850-CTLH
Number of DIMM slot 8
Cache memory capacity 128 GiB to 512 GiB
Data encryption N/A
CBL controller front panel bezel LEDs
The following table describes the denitions of the CBL controller front panel bezel LEDs.
Chapter 2: System controller
Hitachi Virtual Storage Platform G900 Hardware Reference Guide 15