What to do if Hitachi DSP-75AT6N shows overloading on the fan motor?
- LLori CollinsSep 9, 2025
To resolve an overloading issue with the fan motor on your Hitachi Air Compressor, press the RESET button. This issue is detected during operation.
What to do if Hitachi DSP-75AT6N shows overloading on the fan motor?
To resolve an overloading issue with the fan motor on your Hitachi Air Compressor, press the RESET button. This issue is detected during operation.
What to do if Hitachi DSP-75AT6N Air Compressor shows PCB error?
If your Hitachi Air Compressor displays an error indicating PCB error (ROM1)(RAM1) main board memory error, disconnect and then reconnect the power. If the problem continues, replace the PCB.
What to do if my Hitachi Air Compressor shows answer error of 52?
If you encounter an answer error of 52 (CONTACTOR ERR: 52) with your Hitachi Air Compressor, disconnect the power. Check the 52 for proper operation and the wires for tightness. This error is detected during operation or during an emergency stop in Y.
What to do if Hitachi Air Compressor has an instantaneous power interruption?
If your Hitachi Air Compressor experiences an instantaneous power interruption (1 to 5 seconds), restart the unit.
What to do if Hitachi DSP-75AT6N Air Compressor has a brief instantaneous power interruption?
If your Hitachi Air Compressor experiences a brief instantaneous power interruption (1 second or less), restart the unit.
What to do if Hitachi DSP-75AT6N 1st stage discharge air temperature is too high?
If the 1st stage discharge air temperature (HIGH DIS. TEMP. 1) is about 437 [419]°F or higher on your Hitachi Air Compressor, press the RESET button.
What to do if Hitachi DSP-75AT6N Air Compressor shows battery out error?
If your Hitachi Air Compressor displays a 'Battery Out' error due to low battery voltage, disconnect the power and replace the battery with a new one.
What to do if Hitachi DSP-75AT6N shows interstage pressure sensor error?
If your Hitachi Air Compressor displays an interstage pressure sensor error (PRESS.SNSR ERR 1) because PS1 is disconnected, disconnect the power and check the pressure sensor wire for tightness.
What to do if Hitachi Air Compressor shows overloading on the main motor (fixed speed and Vtype)?
To resolve an overloading issue with the main motor on your Hitachi Air Compressor (fixed speed and V-type), press the RESET button. This issue is detected during operation.
What to do if Hitachi Air Compressor oil temperature is too high?
If the oil temperature (OIL HIGH TEMP) reaches 163 [158]°F or higher on your Hitachi Air Compressor, press the RESET button.
Explains the function of each button and display on the instrument panel.
Details the procedure for starting and stopping the air compressor safely.
Guides the user on how to navigate and understand the LCD display.
Lists protective devices and their corresponding shutdown indications and actions.
Provides common problems, their causes, and corrective actions.
Procedures and precautions for installing the air compressor in a suitable location.
Instructions for connecting the compressed air outlet and plant piping.
Covers pre-operation checks and the startup sequence for the air compressor.
Specifies requirements for power supply transformers and cables.
Provides instructions on how to connect the power cable safely.
Explains the load-unload, AUTO, and CPCS control systems.
Outlines daily checks, periodic maintenance, and overhauling intervals.
Provides detailed maintenance schedules based on hours of operation.
Details procedures for replacing filters, cleaning, and depressurizing.
Explains the function of each button and display on the instrument panel.
Details the procedure for starting and stopping the air compressor safely.
Guides the user on how to navigate and understand the LCD display.
Lists protective devices and their corresponding shutdown indications and actions.
Provides common problems, their causes, and corrective actions.
Procedures and precautions for installing the air compressor in a suitable location.
Instructions for connecting the compressed air outlet and plant piping.
Covers pre-operation checks and the startup sequence for the air compressor.
Specifies requirements for power supply transformers and cables.
Provides instructions on how to connect the power cable safely.
Explains the load-unload, AUTO, and CPCS control systems.
Outlines daily checks, periodic maintenance, and overhauling intervals.
Provides detailed maintenance schedules based on hours of operation.
Details procedures for replacing filters, cleaning, and depressurizing.