SUBJECT
Model WHP07600PSDPC9KQ SPECIFICATION
PAGE:2/30
*.COP= Heating capacity (W)
Motor inp
ut (W)
*.Rated Capacity and input are measured with HITACHI inverter circuit by secondary Refrigerant
calorimeter Met
hods of JIS B8606 by SHANGHAI HIGHLY Electrical Appliances Co., Ltd.
Allowable capacity should be more than 95% of the rated capacity and allowable input
should be less than 107% of rated motor input.
2.6 Refrigerant
R290
2.7 Displacement
30.7ml /rev
2.8 Allowable frequency range 900~7200 min
-1
2.9 Oil
HAF68 840±20ml
2.10 Allowable amount of refrigerant
charge
Below 800g
2.11 Compressor cooling Forced air
2.12 Hermetic Terminal
2.13 Space volume of inner case 1500cm
3
2.14 Compressor weight 17.5kg incl. Oil
2.15 Motor Type
Insulation class
Direct current brushless motor E class
2.16
19.9Hz/21.7Hz/24.5Hz
3.
THE PA
RAMETER OF MOTOR
Item
Spec参 数
expl
anation
3.1 Rotor Pole(Pole)
4
——
3.2 Rated Frequency Range(Hz)
30-240
Electrical Frequency,Relating to
VDCmax of Inverter
3.3 Demagnetizing Current(A)
54.01A
Peak Current,at 120℃,-5%
Demagnetizing Rate