H EA T
PU MP WA TE R HEA TE R CO MPR ES SO R CRI TE
RI A
PAGE:6/30
The compressor should be continuously oiled back, and there should be no oil storage part in the refrigeration system
configuration. Also, the oil level in the compressor should meet the conditions in Figure 2. However, when a foam state
occurs and the liquid becomes foamy, this portion does not belong to the oil level. If the oil level is not met, the oil supply
to the sliding part will be insufficient, which
will seriously affect the reliability. (It can be confirmed by a compressor with
a sight glass for observing the oil level).
There should be superheated gas returned to the compressor under all normal operating conditions.
Table 2
Item
Ope
rating Envelope
Dis
charge pressure
MPa
3.13 {30.91}MAX
(co
ndensing temperature :80℃)
see graph 1)
Su
ction Pressure
MPa
0.1
68~0.95 {0.69~8.67}
(Evaporation Temperature :-30℃~25℃)
Co
mpressor case
bottom temp
99℃or be
low and 6 degrees
higher than condensing
temperature
Mo
tor winding temp
R.V
oltage±10%: 120℃ MAX
Ac
cumulator temp
Hi
gher than outlet pipe of evaporator
Am
bient temp
Mee
t for the condition of above mentioned motor winding temp.