P5417086
13
No. Items Optional Function
Individual
Setting
Setting
Condition
Contents Setting
66 FE Not Prepared - - Not Used (Use as 00 conditions)
67 FF Not Prepared - - Not Used (Use as 00 conditions)
68 H1 Not Prepared - - Not Used (Use as 00 conditions)
69 H2 Indication of Hot Start
×
00
01
Indication
No Indication
70 H3 Not Prepared - - Not Used (Use as 00 conditions)
71 H4 Not Prepared - - Not Used (Use as 00 conditions)
72 J1 Not Prepared - - Not Used (Use as 00 conditions)
73 J2 Not Prepared - - Not Used
74 J3 Run Indicator Color
×
00
01
Green
Red
75 J4 Not Prepared - - Not Used (Use as 00 conditions)
76 J5 Not Prepared - - Not Used (Use as 00 conditions)
77 J6 Not Prepared - - Not Used (Use as 00 conditions)
78 J7 Not Prepared - - Not Used (Use as 00 conditions)
79 J8 Eco-operation (*4)(*10)
×
00
01
Not Available
Available
80 J9 Not Prepared - - Not Used (Use as 00 conditions)
81 JA Not Prepared - - Not Used (Use as 00 conditions)
82 Jb Not Prepared - - Not Used (Use as 00 conditions)
83 K1 Not Prepared - - Not Used (Use as 00 conditions)
84 K2 Not Prepared - - Not Used (Use as 00 conditions)
85 K3 Not Prepared - - Not Used (Use as 00 conditions)
86 K4 Not Prepared - - Not Used (Use as 00 conditions)
87 K5 Motion Sensor Detection Level
○
00
01
02
Standard
High
Low
88 K6
Operation Setting during
Thermistor of Wired Controller
or Remote Sensor
○
00
01
02
03
ALL
COOL/DRY
HEAT
ALL
89 K7 Not Prepared - - Not Used (Use as 00 conditions)
90 K8
Control of Dew Condensation
Prevention (*11)
○
00
01
Not Available
Available
91 K9 Not Prepared - - Not Used (Use as 00 conditions)
92 KA Not Prepared - - Not Used (Use as 00 conditions)
93 L1 Not Prepared - - Not Used (Use as 00 conditions)
94 L2 Not Prepared - - Not Used (Use as 00 conditions)
95 L3
Louver Setting during Energy-Saving
Forced Thermo-OFF (*12)
○
00
01
02
03
Receive Air: Low (Standard)
Receive Air: Medium
Receive Air: High
Not Available
96 L4
Fan Speed Up during
Energy-Saving Forced Thermo-OFF
○
00
01
Not Available (Standard)
Available
97 L5
Louver Swing Operation
Energy-Saving Forced Thermo-OFF
○
00
01
Not Available
Available
98 L6 Not Prepared - - Not Used (Use as 00 conditions)
99 L7 Not Prepared - - Not Used (Use as 00 conditions)
100 L8 Not Prepared - - Not Used (Use as 00 conditions)
101 L9 Not Prepared - - Not Used (Use as 00 conditions)
102 LA Not Prepared - - Not Used (Use as 00 conditions)
103 Lb Not Prepared - - Not Used (Use as 00 conditions)
104 P1 Setting Temperature
×
00
01
Every 0.5
o
C
Every 1
o
C
105 P2 Not Prepared - - Not Used (Use as 00 conditions)