--- 11 ---
(6) Mount the Cord [54] according to the following
procedure when replacing the standard cord (cord
armor is integrally molded).
1) Remove the standard cord (cord armor is integrally
molded) according to the procedure of 8-1 (3).
2) Strip the coating on the internal wire of the Cord
[54] about 10 mm from the tip and crimp the
Terminal [50] to the brown or black internal wire as
shown in Fig. 5.
3) Insert the Cord [54] into the Cord Armor D8.8 [51].
4) Cut off the rib for holding the cord of Tail Cover (B)
[46] with nippers as shown in Fig. 6.
5) Mount the Cord [54] and the Cord Armor D8.8 [51]
to Tail Cover (A) [35] and secure them with the
Cord Clip [52] and two Tapping Screws (W/Flange)
D4 x 16 [53] as shown in Fig. 7.
6) Mount each internal wire reversing the removal
procedure. Then mount Tail Cover (B) [46] to Tail
Cover (A) [35] and secure them with the Tapping
Screw (W/Flange) D4 x 25 (Black) [47].
Fig. 6
Fig. 7
Fig. 5
Terminal [50]
Cord [54]
Caulking
A
Stripped
length
10 mm
White
or blue
40 mm
85 mm
Black or brown
A --- A
Tail Cover (B) [46]
A
Approximately
2 mm
(a) For Taiwan
(b) For Singapore and Malaysia
(c) For other countries
: Cut off