MODEL
RA-08MF / RA-08MEF
RA-10MF / RA-10MEF
RA-13MF / RA-13MEF
SAFETY PRECAUTION
●
  Read the safety precautions carefully before operating the unit.
●
  The contents of this section are vital to ensure safety. Please pay special attention to the following sign.
   WARNING ........ Incorrect methods of installation may cause death or serious injury.
   CAUTION ......... Improper installation may result in serious consequence.
   The sign in the fi gure indicates prohibition.
  Be sure that the unit operates in proper condition after installation. Explain to customer the proper way of operating the unit 
as described in the user’s manual.
PRECAUTIONS DURING SHIFTING OR MAINTENANCE
●
 
If abnormal situation arises (like burning smell), please stop the unit and turn off the circuit breaker. 
Fault, short circuit or fi re may occur if the unit is continue to operate under abnormal situation.
●
  Please contact your agent for maintenance. Improper maintenance may cause electric shock and 
fi re.
●  
Please contact your agent if need to remove and reinstall the unit. Electric shock or fi re 
may occur if you remove and reinstall the unit improperly.
WARNING
PRECAUTIONS DURING INSTALLATION
●
  Please ask sales agent or qualifi ed technician for the installation of the unit. Water leakage, short 
circuit or fi re may occur if install the unit improperly.
●
  Please use earth line.
  Do not place the earth line near water or gas pipes, lightning-conductor, or the earth line of telephone. 
Improper installation of earth line may cause electric shock.
●
  A circuit breaker should be installed depending on the mounting site of the unit. Without a circuit 
breaker, the danger of electric shock exists.
●
  Do not install near location where there is fl ammable gas. The unit may catch fi re if  fl ammable  gas 
leaks around it.
●
  If drain pan is used, please ensure that when installing the drain hose, water is able to fl ow  freely 
without any obstruction.
CAUTION
PARTS IDENTIFICATION AND OPERATIONS
 1  Cabinet
 2  Suction Grille
 3 Front Cover
 4  Horizontal Defl ectors
 5  Vertical Defl ector
 6  Air Exhaust Lever
 7  Switch Panel Cover
 8  Auto Swing Switch
 9  Operation Mode Selection Dial
 
10 
 Thermostat Dial
Model
RA-08MF/RA-08MEF
RA-10MF/RA-10MEF
RA-13MF/RA-13MEF
Width
18 
1
⁄
2
”, 470mm
22 
3
⁄
64
”, 560mm
Height
13 
1
⁄
2
”, 345mm
14 
3
⁄
4
”, 375mm
Depth
25 
3
⁄
16
”, 640mm
27 
29
⁄
32
”, 709mm
AUTO SWING
OPERATION MODE SELECTOR DIAL
●
  When the AUTO SWING switch is turned to “ON” position, the vertical defl ectors automatically oscillate right and left 
sweeping the cold air alternately to obtain comfortable cooling.
●
  The vertical defl ectors will stop to swing when the AUTO SWING switch is turned “OFF”
OFF
LO FAN
HI FAN
LO  COOL
HI COOL
Stop the fan and cooling operation.
Fan operation only at low speed.
Fan operation only at high speed.
Cooling operation with low fan speed. This is recommended for sleeping comfort.
Cooling operation with high fan speed for maximum cooling power.
●
  The start of operation will occur an abnormal sound (turbo sound) which doesn’t affect the operation.
THERMOSTAT DIAL
Setting the desired room temperature. Turn the dial further clockwise for cooler indoor temperature.
●
  Do not set the dial to “TEST” for normal usage. This setting is only for technician. If the unit 
is operate at “TEST” for normal use, it may cause the evaporator frosted and consequence 
of no cooling, noisy and water leakage may be found. 
●
  If the evaporator is found frosted, it means the temperature at evaporator is too low. Please 
turn the dial anti-clockwise and check if any obstacle in front of air outlet and inlet like curtain.
●
  When the compressor stops, please wait 3 minutes before turning the dial clockwise.
CAUTIONS
AIR DEFLECTORS
Vertical defl ectors at both sides of outlets can be set to 
either auto-swing or static position to direct discharge air 
rightward, leftward or forward direction.
Horizontal defl ectors at both sides of the outlets can 
be set to direct discharge air upward, downward or 
forward direction.
VERTICAL DEFLECTORS HORIZONTAL DEFLECTORS
To avoid dew forming on the defl ectors which eventually may drip to the fl oor, please do not adjust horizontal defl ectors 
extremely downward position or vertical defl ectors extremely leftward or rightward position during cool operation for a long 
time.
Also, do not adjust the vertical defl ectors position by hand or any other object.
CAUTIONS
AIR EXHAUST LEVER
WASABI AIR PURIFYING FILTER
Set the air exhaust lever to the down ( OPEN) position for air        
ventilation in the room. The air exhaust lever should normally be kept 
in up ( CLOSE) position during cooling operation and in the case of 
typhoon.
Always stop the operation before installing the wasabi air purifying fi lter.
Wasabi air purifying fi lter are not washable. It is recommended to use vacuum to clean it. It can be used use for 1 year 
time. Type number for this  wasabi air purifying fi lter is <SPX-CFH9W>. Please use this number for ordering when you 
want to renew it.
1. Pull and remove the suction grille 2. Remove the pre-fi lter 3. Install the wasabi air purifying 
fi lter in the frame
4. Install back the pre-fi lter  and 
close the suction grille
NOTES ON OPERATION
TEMPERATURE AND HUMIDITY
Avoid to use the room air conditioner for cooling operation when the outside temperature is below 21°C (70°F). Recommended 
operation humidity should be below 80%. Continuous operation at over 80% humidity (indoor) will cause some dews form 
on the outlet grille and defl ectors of the unit.
NOISE
In a quiet environment during the starting or stopping the operation, phenomena like fl owing sound of refrigerant in the 
refrigerating cycle and rubbing noise from the fan casing may occasionally occur, but this is normal for the operation.
Water will be condensed on the evaporator coil and collected in the bottom tray, it is picked up by the condenser fan and 
blown onto the condenser coil, this creates a “splashing” sound which is normal.
ODOR
The odor will possibly be emitted from the room air conditioner especially at the starting of operation and in a high 
humidity condition. This is not abnormal phenomena because of the various kind of odors emitted by smoke, food stuffs, 
cosmetics and others which may stick to the room air conditioner. So, the pre-fi lter and the evaporator regularly must be 
cleaned to reduce the odor.
THE IDEAL WAYS OF OPERATION
Suitable Room Temperature
   Warning
Freezing temperature 
is bad for health and a 
waste of electric power.
Install curtain or blinds
It is possible 
to reduce heat 
entering the room 
through windows.
Ventilation
 Caution
Do not close the room for a long period of 
time. Occasionally 
open the door and 
windows to allow the 
entrance of fresh air.
Do Not Forget To Clean The Pre-Filter
Dusty pre-fi lter will reduce the air 
volume and the cooling effi ciency. 
To prevent from wasting electric 
energy, please clean the pre-fi lter 
every 20 days.
Please Adjust Suitable Temperature 
For Baby And Children
Please pay attention to the 
room temperature and air fl ow 
direction when operating the 
unit for baby, children and old 
people who have diffi culty in 
movement.
FOR USER’S INFORMATION
The Air Conditioner And The Heat Source In The Room
    Caution
If the amount of heat in the room is above the cooling capability of the air conditioner (for 
example: more people entering the room, using heating equipments and etc.), the preset 
room temperature cannot be achieved.
When Lightning Occurs
    Warning
To protect the unit during lightning, please stop operating the unit and remove the plug 
from the socket.
<
IA0000: A 
>
WINDOW  TYPE  ROOM  AIR  CONDITIONER 
OPERATION  AND  INSTALLATION  MANUAL
WARNING