(The QLO does not work.)
I
Do not insert anything like slender stick
into the discharge air plenum or return air
grille as the fan is running at high speed,
it is highly likely to cause danger.
When thunder is likely to happen, for
protecting the machine, stop operation
and turn off the power switch to prevent
from failure.
Press the button. Cooling operation starts with a beep. Press the button again to stop operation. The
cooling function does not start if the temperature setting is higher than the current room temperature (even
though the “RUNNING” (OPERATION) lamp Iights). The cooling function will start as soon as you set the
temperature below the current room temperature.
DEHUMIDIFYING OPERATION
Use the device for dehumid ifying when the room temperature is above 16°C.
When it is under 15°C, the dehumidifying function will not work.
C
A
u
T
N
C
A
U
T
I
0
N
UNIT DISPLAY
INVERTER
INDICATION DISPLAY ON THE FRONT COVER
FAN SPEED indicator light
When the unit is running, the light turns on.
When you press this button, the intensity of circulation
will change from (AUTO) to (HI) to (ME) to (LO) incycle.
POWERFUL indicator light
Use these buttons to start powerful operation.
When the uni
t is performing a powerful operation, this
light turns on.
Room temperature display
When the unit is powered up, the computer will
automatically detect the room temperature and
display the current temperature.
(Indicates the error code when an error occurs)
AUTO SWING indicator light
When you press the button, the vertical louver will
automatically be swinging.
TIMER indicator light
When the unit is preset with a timer, this light turns on.
Infrared light receiving window
A “beep” sound will be generated when it receives the
signal from the remote controller.
REMOTE CONTROLLER
MODE indicator Iight
When the unit is running, the light turns on.
When you press this button, the mode will change
,
from (COOL) to (FAN) to (DRY) incycle.
ON/OFF button
Press this button to start operation, press it again
to stop operation.
• Use only on single outlet circuit exclusive for the air conditioner.
• Ensure the mounting support is firm and steady or there is a risk the unit may fall.
Johnson Controls-Hitachi Air Conditioning Philippines, Inc.
1A Binictican Drive, Subic Bay Industrial Park Phase II Subic Bay Freeport Zone, Philippines
TEL: (02)362-4847
TEL(SERVICE): (02)362-3842
W
A
R
N
I
N
Read this section of “Safety precaution” carefully to understand proper usage of this unit before use.
Pay special attentions to Warning” and Caution” designations contained in this manual. The Warning"
designation may cause death a serious of injury if not followed correctly. Failure to follow the instructions under the
Caution” designation may also cause possible serious consequence depending on the situation. Therefore, be
sure to observe these designations for your safety.
In addition, this sign shown in the diagram denotes prohibited items, whereas denotes mandatory items.
Be sure to keep this manual after reading.
The manufacturer is not liable for maintenance and repair of the air conditioner as stipulated in the warranty. The
same condition applies to any damage to this unit body/nearby property if you fail to observe warning instructions in
this manual/use of parts not supplied from us.
This product uses non-flammable R410A refrigerant. While the product is under installation or transport, except R410A
refrigerant, please do not charge other refrigerants, air, oxygen, propane, alcohol, or any flammable material to avoid
machine damage, blaze, or explosion. Be sure to use the refrigerant specified by the manufacturer.
• If there is an error (burning odor, etc.), stop operation and turn off the power switch and then notify the
service center or the dealer from where the air conditioner was purchased. If the air conditioner keeps on
running with the error, it may lead to failure, electric shock, fire, etc.
• To service the air conditioner, directly contact the service center or the dealer from where the air conditioner
was purchased. If it is improperly repaired by yourself, there is a risk of electric shock or fire.
• If the air conditioner is to be moved or relocated, directly contact the service center or the dealer from where
the air conditioner was purchased. If it is moved or relocated improperly by yourself, there is a risk of electric
shock or fire.
DC
• If the power cord is damaged, it must be replaced by the manufacturer or by the service
center or a technician to prevent danger
Operation manual
Window Inverter Type
Room Air Conditioner
Air conditioner installation and its electrical wiring require a professional. Therefore, assign
only an authorized dealer or a certified technician to install your air conditioner and perform
its electrical wiring. Do not attempt to do it by yourself (charges are additional). If improperly
performed by yourself, it may cause leakage, electric shock or fire.
Do not use a metal wire or copper wire as a fuse to prevent from failure or fire.
W
A
R
N
I
N
G
When installing, do not use an extended power cord or a power cord with excess bending
(radius less than 20mm). Also, use the cable tie supplied with the base-pan to secure it. Do not place the
cord inside the unit body or it may cause short circuit or abnormal heat leading to a fire due to insulation
damage by an overly compressed cord.
C
A
U
T
I
O
N
Temperature button
Press this button to raise or lower the temperature.
When cleaning the unit body, never wash
it with splashing water as there is a risk
of current leakage.
Do not let the discharge air plenum
directly face your body for a long
period of time, or it may have
adverse effect to health.
W
A
R
N
I
N
G
C
A
U
T
I
O
N
• Do not operate the switch when your
hand is wet to prevent electric shock.
If a gas stove is used while the air
conditioner is operating, be sure to
open the window often, or it is possible
to have insufficient oxygen inside.
• If the machine will not be used for a
long period of time, turn off the power
switch for safety.
• Do not place animals or plants at the place
to where the airflow is blowing directly, or
it will have adverse effect to them.
Press the button so that the display indicates "COOL".
Set the desired FAN SPEED with the button (the display indicates the
setting).
AUTO : The FAN SPEED is HI at first and varies to ME automatically when the preset
temperature has been reached.
Set the desired room temperature with the buttons. The temperature setting and
the actual room temperature may vary somewhat depending on conditions.
Press the button so that the display indicates “DRY” (DEHUMIDIFY).
The FAN SPEED is set at “LO” automatically.
Press the button.
COOLING OPERATION
Use the device for cooling when the outdoor temperature is above 10°C. If humidity is very high
(over 80%) indoors, some dew may form on the air outlet grille of the indoor unit.
Operating range of cooling: Indoor 21°C~3C, Outdoor 10°C~42°C
21°C -32°C ' outdoor 10°C -4C.
SAFETY PRECAUTIONS
PRECAUTIONS DURING SHIFTING OR MAINTENANCE
FUNCTIONS LIST AND FEATURES
USAGE PRECAUTIONS
INSTALLATION PRECAUTIONS
RA-08HVQC
RA-10HVQC
Do not let the airflow directly face the
gas stove, or it is likely to cause
incomplete combustion.
When cleaning the unit body, be sure to turn
off the power switch, or it may cause injury
as the fan is running at high speed inside.
IMPORTANT:
READ AND UNDERSTAND THIS
MANUAL BEFORE USING THIS
AIR CONDITIONER.
KEEP THIS MANUAL FOR
FUTURE REFERENCE.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi RA-10HVQC and is the answer not in the manual?

Hitachi RA-10HVQC Specifications

General IconGeneral
BrandHitachi
ModelRA-10HVQC
CategoryAir Conditioner
LanguageEnglish

Related product manuals