BASIC MODE
Operation mode
Control function
Fan Cooling Sensor dehumidification Heating Automatic
1
Start/stop button,
basic mode
2
Timer
operation
ON timer
OFF timer
Start/stop button
operation lamp
Operation and stop are repeated
independent of timer reservations
Start/stop button
Reservation
Cancel
Operation lamp
Timer lamp
Timer memory
(OFF timer during stop) (Cancel)
(Change of the reservation time)
Start/stop button
Reservation
Cancel
Operation lamp
Timer lamp
Timer memory
(ON timer during operation)
(Cancel)
(Change of the reservation time)
5
6
Heating load reduction and Pd cut
Reversing valve lock protection
AIR BLOW CHANGE TO "H" FORCILY BY INPUTING "PD CUT 2"
AIR BLOW MAKE A POSSIBLE TO CHANGE AIR BLOW AT TEMP. T
7
.
AIR BLOW RETURN TO THE ORIGINAL SETTED TEMP. AT TEMP T
5
.
All relays are stopped by low-
temperature input.
Not accepted during hot keep,
during compressor stop, during
defrosting and during forced
3 minutes.
Accepted only during heating
operation.
Receovery at the time of stop by
low-temperature input is reset
recovery.
The timer lamp flashes at the
time of stop.
– 31 –
T
9
T
8
T
6
T
7
T
5
T
3
T
4
TEMPERATURE OF INDOOR HEAT
EXCHANGER THERMISTOR
PD CUT 1
PD CUT 2
PD CUT 3
FAN RELAY H
FAN RELAY L
POWER RELAY
STICK RELAY
EXTERNAL FAN RELAY
4-WAY VALVE RELAY
(0.5)(0.5)
(0.5)(0.5) (0.5)(0.5)
(0.5)(0.5)
(0.5)(0.5)
(0.5)(0.5)
(0.5)(0.5)
(0.5)(0.5)
1 sec1 sec
1 sec1 sec
(1 sec)(1 sec)
Fan relay H
Power relay
Stick relay
External fan relay
Reversing valve relay
Timer lampTimer lamp
Indoor heat exchangerIndoor heat exchanger
thermistor temperature
T
1
Low-temperature inputLow-temperature input
Automatic
MED
LO
HI
Operation in the previous
circulation mode
Operation in HI mode
Operation in MED mode
Operation in LO mode
Same as on the left.
Same as on the left.
Same as on the left.
Only circulation
with cut velocity is
executed, independent
of the thermostat
signal.
(1) Strong
3
Circulation
mode
Thermostat operation
H [ HI
L [ MED
S [ LO
The power relay is
delayed by 2 seconds
from the start of
thermostat operation.
(1) In case of Automatic mode
Note:
The min. ON time of the power relay
is 3 minutes, and the min. OFF time
also is 3 minutes.
(2) In other modes than Automatic
Same as above (but operation is
made with the velocity set at the
time of operation start).
HI, MED, or LO operation is
executed according to the thermostat
signal. (Refer to Thermostat operation.)
LO and Stop are repeated according to the thermostat
signal, independent of the setting.
Notes:
Forced operation by start/stop
button ON is executed even
with thermostat OFF.
The room temperature 30 sec
after operation start, minus
0.66 deg, becomes the set
temperature.
When the room temperature
is 16˚C or lower, 16˚C
becomes the set temperature.
The other operations are the
same as for (1).
Air-blow mode (A) (B)
HL H
LL L
SS S
Automatic L
X
L
HI, MED, LO, and Stop are repeated according to the thermostat
signal and time.
HI, MED, LO, and Stop are repeated according to the thermostat
signal and time.
MED, LO, and Stop are repeated according to the thermostat signal
and time.
LO and Stop are repeated according to the thermostat signal and time.
The Automatic speed mode
for each operation mode is used
independent of the setting.
(Week at the time of Sensor
dehumidification.)
The operation mode at the
start of operation differs as
shown below according to
the room temperature.
Room temperature
p
at the start of
[
operation
A shift is not accepted at the
time of operation start.
There is no switching between
modes after start of operation.
When the operation is started
again within 20 min. after
stop with the start/stop button,
operation will be executed in
the previous mode.
The operation details are the
same as for each operation mode.
The set temperature is set with
the room temperature
adjustment button. Correction
by V, ±3˚C is possible with.
At this time, the operation mode
judgement temperature also is
shifted at the same time.
However, correction is possible
only in cooling operation mode,
but not in Sensor dehumidific-
ation mode.
Cooling The set temper-
ature shall be 27˚C.
Sensor The set temper-
dehumidi- ature shall be 2
fication degrees below the
room temperature
at the start of
operation.
Heating The temperature
shall be 23˚C +
temperature shift
amount.
27˚C
23˚C
(2) Set temperature higher than room temperature
(1) When the set temperature is lower than the room temperature
Example for HI circulation mode
4
Notes:
The min. ON time of the power relay is 3 minutes, and the min. OFF time
also is 3 minutes.
In automatic circulation mode, HI in section (B) occurs only the first time.
Start/stop button
Start/stop button
Fan relay H
Fan relay H
Stick relay
Stick relay
2 sec
2 sec
2 sec2 sec
+3
+2
+1
-1
-2
-3
Set temperature
Set temperature
Start/stop button
Start/stop button
Fan relay H
Fan relay H
Fan relay L
Fan relay L
Fan relay S
Fan relay S
Power relay
Power relay
Stick relay
Stick relay
External fan relay
External fan relay
Operation lamp
Operation lamp
H S L S L H S
H S L S L H S
S L L
S L L
+3
+2
+1
-1
-2
-3
Set temperature
Start/stop button
Fan relay S
Power relay
Stick relay
Operation lamp
S S S
5 sec
2 sec
5 sec
2 sec
2 sec
External fan relay
-1
-2
-3
-4
0.66 deg
0.33 deg
Set temperature
Start/stop button
Fan relay S
Power relay
Stick relay
Operation lamp
30 sec
2 sec
5 sec
2 sec
External fan relay
15 sec
30 sec
30 sec
15 sec
30 sec
30 sec
15 sec
30 sec
30 sec
+3
+2
+1
-1
-2
-3
-4
(Set temperature)+(Set temperature)+
(Temperature shift amount)(Temperature shift amount)
Start/stop switch
Fan relay H
Fan relay L
Fan relay S
Power relay
Stick relay
External fan relay
4 way valve relay4 way valve relay
Pilot lampPilot lamp
Hot keep lampHot keep lamp
S
S
L
H
S
H
S
L
B
S L
S
L
H
2 sec
2 sec
2 sec
2 sec
30 sec
30 sec
H
The min. ON time of the power relay is 3 minutes, and the min.
OFF time also is 3 minutes.
The indoor fan is not delayed with operation start by start/
stop button ON.
The indoor fan is delayed by 5 sec with operation start
by thermostat operation.