RAM-130QH5
Cooling
Combination
of Indoor Unit
TotalCapacity Rating Total Power Ampere(A)
– EER
Capacity Rating
Total
Power Ampere(A)
– EER
(kW)
(kW) (kW) (Range) (kW) Consumption(W) at 230V (kW) (Range) Consumption(W) at 230V
Outdoor UnitOutdoor Unit
One Unit
Heating
1.8
1.8
1.80
1.80
560
2.5 3.21 A
2.50
2.50
750
3.3 3.33 C
(1.00-2.50) (200-750) (1.10-3.20) (200-1050)
2.5
2.5
2.50
2.50
780
3.4 3.21 A
3.90
3.90
1145
5.0 3.41 B
(1.00-2.80) (200-980) (1.10-4.70) (200-1380)
3.5
3.5
3.50
3.50
1160
5.1 3.02 B
4.80
4.80
1550
6.8 3.10 D
(1.00-3.90) (200-1280) (1.10-5.80) (200-1870)
5.0
5.0
5.00
5.00
1780
7.8 2.81 C
6.50
6.50
2400
10.5 2.71 E
(1.00-5.60) (200-1960) (1.10-7.20) (200-2660)
1.8+1.8
3.6
1.80+1.80
3.60
1190
5.2 3.03 B
2.50+2.50
5.00
1460
6.4 3.42 B
(1.50-4.00) (200-1300) (1.50-5.20) (200-1550)
1.8+2.5
4.3
1.80+2.40
4.20
1310
5.8 3.21 A
2.40+3.80
6.20
1820
8.0 3.41 B
(1.50-4.60) (200-1450) (1.50-6.30) (200-1920)
1.8+3.5
5.3
1.70+3.30
5.00
1650
7.2 3.03 B
2.30+4.50
6.80
1995
8.8 3.41 B
(1.50-5.60) (200-1820) (1.50-7.20) (200-2100)
1.8+5.0
6.8
1.40+4.00
5.40
1795
7.9 3.01 B
2.00+5.00
7.00
2050
9.0 3.41 B
(1.50-5.90) (200-1980) (1.50-7.20) (200-2100)
2.5+2.5
5.0
2.50+2.50
5.00
1650
7.2 3.0 B
3.40+3.40
6.80
2015
8.8 3.37 C
(1.50-5.60) (200-1820) (1.50-7.20) (200-2100)
2.5+3.5
6.0
2.17+3.03
5.20
1730
7.6 3.01 B
3.15+3.85
7.00
2070
9.1 3.38 C
(1.50-5.70) (200-1900) (1.50-7.20) (200-2100)
3.5+3.5
7.0
2.70+2.70
5.40
1795
7.9 3.01 B
3.60+3.60
7.20
2110
9.3 3.4 B
(1.50-5.90) (200-1980) (1.50-7.20) (200-2110)
2.5+5.0
7.5
1.80+3.60
5.40
1795
7.9 3.01 B
2.70+4.50
7.20
2110
9.3 3.41 B
(1.50-5.90) (200-1980) (1.50-7.20) (200-2110)
3.5+5.0
8.5
2.20+3.20
5.40
1995
8.8 2.71 D
3.05+4.15
7.20
2110
9.3 3.41 B
(1.50-5.90) (200-2200) (1.50-7.20) (200-2110)
1.8+1.8+1.8
5.4
1.80+1.80+1.80
5.40
1780
7.8 3.03 B
2.33+2.33+2.33
7.00
1850
8.2 3.78 A
(1.50-6.00) (200-2200) (1.50-7.20) (200-2110)
1.8+1.8+2.5 6.1
1.80+1.80+2.50
6.10
2020
8.9 3.02 B
2.00+2.00+3.20
7.20
1900
8.4 3.79 A
(1.50-6.40) (200-2200) (1.50-7.20) (200-2110)
1.8+1.8+3.5
7.1
1.60+1.60+3.10
6.30
2095
9.2 3.01 B
1.85+1.85+3.50
7.20
1900
8.4 3.79 A
(1.50-6.60) (200-2200) (1.50-7.20) (200-2110)
1.8+1.8+5.0
8.6
1.30+1.30+3.70
6.30
2095
9.2 3.01 B
1.60+1.60+4.00
7.20
1900
8.4 3.79 A
(1.50-6.60) (200-2200) (1.50 -7.20) (200-2110)
1.8+2.5+2.5
6.8
1.70+2.30+2.30
6.30
2095
9.2 3.01 B
1.80+2.70+2.70
7.20
1900
8.4 3.79 A
(1.50-6.60) (200-2200) (1.50-7.20) (200-2110)
1.8+2.5+3.5
7.8
1.50+2.00+2.80
6.30
2095
9.2 3.01 B
1.60+2.50+3.10
7.20
1900
8.4 3.79 A
(1.50-6.60) (200-2200) (1.50-7.20) (200-2110)
1.8+3.5+3.5
8.8
1.30+2.50+2.50
6.30
2095
9.2 3.01 B
1.40+2.90+2.90
7.20
1900
8.4 3.79 A
(1.50-6.60) (200-2200) (1.50-7.20) (200-2110)
2.5+2.5+2.5
7.5
2.10+2.10+2.10
6.30
2095
9.2 3.01 B
2.40+2.40+2.40
7.20
1900
8.4 3.79 A
(1.50-6.60) (200-2200) (1.50-7.20) (200-2110)
2.5+2.5+3.5
8.5
1.85+1.85+2.60
6.30
2095
9.2 3.01 B
2.23+2.23+2.74
7.20
1900
8.4 3.79 A
(1.50-6.60) (200-2200) (1.50-7.20) (200-2110)
(1.8+1.8)+(1.8+1.8) 7.2
(1.80+1.80)+(1.80+1.80)
7.20
2380
10.5 3.03 B
(2.50+2.50)+(2.50+2.50)
10.00
2920
12.8 3.42 B
(1.50-8.00) (200-2600) (1.50-10.40) (200-3100)
(1.8+1.8)+(1.8+2.5)
7.9
(1.80+1.80)+(1.80+2.40)
7.80
2500
11.0 3.12 B
(2.50+2.50)+(2.40+3.80)
11.20
3280
14.4 3.41 B
(1.50-8.60) (200-2750) (1.50-11.50) (200-3470)
(1.8+2.5)+(1.8+2.5) 8.6
(1.80+2.40)+(1.80+2.40)
8.40
2620
11.5 3.21 A
(2.40+3.80)+(2.40+3.80)
12.40
3640
16.0 3.41 B
(1.50-9.20) (200-2900) (1.50-12.60) (200-3840)
(1.8+1.8)+(1.8+3.5) 8.9
(1.80+1.80)+(1.70+3.30)
8.60
2840
12.5 3.03 B
(2.50+2.50)+(2.30+4.50)
11.80
3455
15.2 3.42 B
(1.50-9.60) (200-3120) (1.50-12.40) (200-3650)
Multizone Combinations
45
Two UnitsThree UnitsFour Units