ā 29 ā
CONSTRUCTION AND DIMENSIONAL DIAGRAM
Note:
1. Service space (free space needed for servicing) is 200mm on the right, 100mm on the left and 50mm on top.
2. The wide and narrow pipes must be thermally insulated.
3. Piping length is within 30m
4. Height different of the piping between the indoor unit and the outdoor unit should be within 20m.
5. Power supply cord length is about 2m
6. Connecting cable 2.5mm dia. x 3 (AB Line), 1.6mm dia. x 2 (CD Line) is used for the connection.
Unit : mm
Wireless remote controller
147
56 17.5
About
380
Viewed from back
(bottom direction pipe
lead-out)
D
C
B
A
L
N
D
C
B
A
Indoor Unit
Outdoor Unit
Connecting
Cord
Power
supply
cord
MODEL RAS-70YH7
When piping is drawn
horizontally, exchange
the drain hose for the
drain cap.
Front panel
Suction grill
245
70
8
60