ā 87 ā
By connecting CN3 and CN4.
Check the voltage between "+1
5V" and 
"15-0V" on power P.W.B.
By disconnecting CN3 and CN4.
Check the voltage between "+15V" 
and "15-0V" on power P.W.B.
Diagnosis procedure of IPM using multimeter.
<Inverter section>
  Set the multimeter function to resistance x 100.If the multimeter dose not have x 100 range, please select  
  its range from x 1 to  x 100.
  The judgment shall be OK. When the measurement was high resistance.
  (Please consider that the probe polarity will be reserve when use a digital mulimeter due to its battery    
  connection inside)
<note>
  Sometimes, it may misjudge as OK because of low conductivity when power module was damaged as    
  disconnect mode. In this case, please  check the resistance by reversing the probe polarity and consider   
  OK when it was low resistance. Also, it is OK if the resistance was as same as the other phases (U,V,W).
<Driver circ
uit (internal IC)>
 
15V will not be generated when the internal 
IC has malfunctioned.
 To find the malfunction either the power 
supply of power P.W.B or internal IC, please follow the      
  procedure following.
Replace P.W.B.
Lower 
(than 15V)
Lower 
(than 15V)
Power P.W.B. may malfunction.
(Replace power P.W.B.)
Normal(15V)
Normal(15V)
Internal IC is OK.
Driver IC which is in IPM may 
malfunction.(Replace main P.W.B.
)
08A395_RAS_35YH6_083-093_E 2008.03.10, 15:5087