60
11. High static-pressure switch (Full duct type and semi duct type)
For full duct type and semi duct type, set the high to HIGH STATIC-PRESSURE.
If not set to HIGH, there will be reduction of cooling and heating capacities.
Fig. 13-1
Micro computer
Buzzer
Temporary
switch
Main P.W.B.
Operate
LED
Timer
LED
Static pressure sw
High
Drain pump test drive sw
Normal
12. Wired remote control receiver circuit
In wired remote control receiver circuit, the signal will transmit to micro computer pin 3 by using
photocoupler PC101.
Wired remote control
CN18
C551
C550
R771 R770
R611
C611
PC101
5V
0V
0V
Wired input
Microcomputer
1
2
3
13
+
Fig. 11-1