EasyManua.ls Logo

Hitachi RAS-5FS3 User Manual

Hitachi RAS-5FS3
384 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Models
<Indoor Units>
In-the-Ceiling Type
RPI-0.8FSG1 RPI-2.5FSG1 RPI-8FSG1
RPI-1.0FSG1 RPI-3.0FSG1 RPI-10FSG1
RPI-1.5FSG1 RPI-4.0FSG1
RPI-2.0FSG1 RPI-5.0FSG1
4-Way Cassette Type
RCI-1.0FSG2 RCI-2.5FSG2 RCI-5.0FSG2
RCI-1.5FSG2 RCI-3.0FSG2
RCI-2.0FSG2 RCI-4.0FSG2
2-Way Cassette Type
RCD-1.0FSG1 RCD-2.5FSG1 RCD-5.0FSG1
RCD-1.5FSG1 RCD-3.0FSG1
RCD-2.0FSG1 RCD-4.0FSG1
•Wall Type
RPK-1.0FSGM6 RPK-2.0FSGM6
RPK-1.5FSGM6 RPK-2.3FSGM6
Floor Type
RPF-1.0FSG(E) RPF-1.5FSG(E)
Floor Concealed Type
RPFI-1.0FSG(E) RPFI-1.5FSG(E)
Ceiling Type
RPC-2.0FSG1 RPC-3.0FSG1 RPC-5.0FSG1
RPC-2.5FSG1 RPC-4.0FSG1
<Outdoor Units>
FSG(1) Series
RAS-5FSG RAS-16FSG RAS-24FSG1
RAS-8FSG RAS-20FSG RAS-30FSG1
RAS-10FSG
•FS3, FS5 Series
RAS-5FS3 RAS-16FS3 RAS-24FS5
RAS-8FS3 RAS-20FS3 RAS-30FS5
RAS-10FS3
FXG Series
RAS-8FXG RAS-10FXG
FX3 Series
RAS-8FX3 RAS-10FX3
<System Equipment>
•Total Heat Exchangers
KPI-2521 KPI-5021 KPI-8021 KPI-10021
This service mamual provides the technical
information for the HITACHI Inverter-Driven
Multi-Split System Heat Pump Air
Conditioners, “SET FREE, FSG(1)/FS3, FS5
and FXG/FX3 Series”.
Read this manual carefully before starting
service activities.
HITACHI INVERTER-DRIVEN
MULTI-SPLIT SYSTEM
HEAT PUMP AIR CONDITIONERS
SET FREE FSG(1)/FS3, FS5 SERIES
AND
SET FREE FXG/FX3 SERIES
P5413553

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Hitachi RAS-5FS3 and is the answer not in the manual?

Hitachi RAS-5FS3 Specifications

General IconGeneral
BrandHitachi
ModelRAS-5FS3
CategoryAir Conditioner
LanguageEnglish

Summary

Troubleshooting Guide

Initial Troubleshooting Steps

Covers initial checks, wiring, and basic diagnostics for common operational issues.

Troubleshooting by Alarm Codes

Provides detailed guidance on diagnosing issues based on specific alarm codes indicated by the system.

Component-Specific Checks

Detailed procedures for self-checking PCBs, remote controls, and other critical system components.

System Test Run Procedures

Instructions for performing test runs via remote control or outdoor unit to verify system operation.

Servicing Procedures

Outdoor Unit Servicing

Detailed procedures for disassembling, inspecting, and replacing components within the outdoor unit.

In-the-Ceiling Unit Servicing

Specific servicing instructions for RPI models, covering filter, PCB, fan, and thermistor removal.

4-Way Cassette Unit Servicing

Procedures for servicing 4-way cassette units, including filter, grille, PCB, and fan motor removal.

Wall Type Unit Servicing

Step-by-step guide for servicing wall-mounted indoor units, including filter, panel, and motor removal.

Indoor Unit Heat Exchanger Cleaning

Guidelines and required tools for safely cleaning heat exchangers across various indoor unit types.

Main Parts Identification and Specifications

Inverter Specifications and Protection

Details on inverter specifications, protection functions, and abnormalities for different power sources.

Scroll Compressor Principles and Structure

Explanation of the scroll compressor's mechanism for low vibration, low sound, and compression principle.

Thermistor Locations and Characteristics

Identifies thermistor positions in indoor and outdoor units and provides resistance characteristics.

Electronic Expansion Valve Specifications

Details on outdoor and indoor electronic expansion valves, including wiring, drive method, and coil resistance.

Optional Functions and Settings

Indoor Unit Optional Functions

Covers optional functions for indoor units like remote control, power supply settings, and thermostat control.

Outdoor Unit External Signal Settings

Details on setting external signals for the outdoor unit, including demand and forced stoppage.

Remote Control Switch Features

Overview of remote control switch parts, operation systems, and settings for multiple units.

Wireless Remote Control Switch Operations

Instructions for installation, identification, and simultaneous operation of wireless remote controls.

Field Work Instructions and Best Practices

Field Issue: Compressor Burnout from Low Refrigerant

Analysis of compressor burnout due to insufficient refrigerant charge, including cause and countermeasures.

Field Issue: Poor Cooling with Long Piping

Diagnosing insufficient cooling performance caused by long piping and improper dip switch settings.

Field Issue: High Operating Sound in Ceiling Units

Troubleshooting high operating sound in ceiling units due to installation factors affecting airflow.

Installation Notes for SET-FREE FXG/FX3 Series

Important considerations for installing SET-FREE FXG/FX3 series, including site selection and piping work.

Routine Maintenance Procedures

Guidelines for routine maintenance of indoor and outdoor units, covering fans, heat exchangers, and electrical components.

Related product manuals