EasyManua.ls Logo

Hitachi RAD-18NH7A - Page 48

Hitachi RAD-18NH7A
107 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
58
7. Drain pump drive circuit
When cool or dehumidifying operation, pin 58 of the micro computer goes Hi, Q333 and Q932 turn on
and the drain pump drive.
0V
L933 R931
R932 C932
Q933
Q932
L932
D932
21V
RED
Drain pump motor
BLK
CN3
0V
0V
58
Micro computer
Drain pump
3
1
8. Drain pump trial run switch
This switch forcibly turns the drain pump on. When the drain pump trial run switch is turned on, the
timer indicator will blink seven times, and no remote signal will be accepted.
0V
5V
R533
Drain pump
trial run SW
(normally, Hi)
R534
Microcomputer
52
9. Float switch
This is a float type switch that monitors the drain level of drain pan. The switch will be activated and
will stop operation if the drain pump is faulty or drain hose is stopped up, disabling drainage, causing the
drain level to rise abnormally.
When the float switch is activated, the timer indicator will flash six times. Note that the float switch will
also be activated, disabling operation if the connector of float switch has defective contact or is
connected incompletely.
0V
0V
0V
5V
R621C620R539Microcomputer
R620
CN16
FLOAT SW
Normally Hi (4.5V)
53
1
2
+
Fig. 7-1

Other manuals for Hitachi RAD-18NH7A

Related product manuals