– 35 –
MAINTENANCE
Cleaning and maintenance must be carried out when lter lamp lights. Before cleaning, stop operation and
switch off the power supply.
1. PRE-FILTER
Clean the pre- lter, as it removes dust inside the room. In case the pre- lter is full of dust, the air ow
will decrease and the cooling capacity will be reduced. Further, noise may occur. Be sure to clean the
pre- lter following the procedure below.
!
CAUTION
1
Open the front panel and remove the pre- lter
Gently lift and remove the air purifying lters
from the pre- lter frame.
2
Vacuum dust from the pre- lter and air purifying
lter using vacuum cleaner. If there is too much
dust, rinse under running tap water and gently
brush it with soft bristle brush. Allow pre- lters to
dry in shade.
3
Re-insert the air purifying lter to the pre- lter
frame. Set the pre- lter with “FRONT” mark
facing front, and slot them into the original state.
After attaching the pre- lters, push the front
panel at three arrow portions as shown in gure
and close it.
!
CAUTION
Do not wash with hot water at more than 40°C. The pre- lter may shrink.
When washing it, shake off moisture completely and dry it in the shade; do not expose it directly to the
sun. The pre- lter may shrink.
PROCEDURE
RAK-18-25-35-50NHA2-3 35RAK-18-25-35-50NHA2-3 35 6/3/14 11:40 AM6/3/14 11:40 AM