HOW TO OPERATE USING THE SERVICE SWITCH THE OUTDOOR UNIT
MODEL RAC-08 10
1. Tu r n off the power switch.
2. Remove the electrical box cover.
3. Tu r n on the power switch.
4. After waiting for 30 seconds, push the service switch for a second.
LD303 (red) will light and the unit will operate in the forced cooling mode at this time.
Never operate the unit for
more than 5 minutes.
(Cautions)
(1) If interface signal (DC 35V) terminals C and D are not connected when the outdoor unit is in forced cool mode,
the outdoor unit defect indicator (LD301) will blink 9 times during operation to indicate communication error.
(2) If checking is done with the compressor connector disconnected, the unit will stop
and LD301 will blink 4 times.
Be sure to push the service switch for a second again to stop the forced cool operation.
HOW TO OPERATE THE OUTDOOR UNIT INDEPENDENTLY
1. Connect the large dia. pipe side and small dia. pipe side service valve using a pipe.
Parts to be prepared
(1) Reducing union
2/8” (6.35 mm)
3/8” (9.52 mm)
(2) Copper pipe (2/8” and 3/8”)
Connect the small diameter service
value and the large diameter service
valve using the reducing union and
copper pipe as shown on the right.
Charge refrigerant of 300g
after vacuuming (
1
)
The operation method is the same as “How to operate using the connector to servicing the outdoor unit.
1
The charging amount of 200g is equivalent to the load in normal operation.
Do not operate for more than 5
minutes
Large dia. service valve
Reducing union
(2/8” and 3/8”)
Copper pipe
(2/8”)
Small diameter
service valve
Reversing
valve
Compressor
Outdoor unit
S
ervice switch
LD30
3
LD
302
LD
3
0
1
MAIN
P
W
B
S
E
R
VICE SWIT
C
H
H
I
C
Electrical box cover
Unit top cover
DC VOLTAGE CHECKPOINT(-)IPM(33)#PIN
DC VOLTAGE CHECKPOINT(+)IPM(25)#PIN
SELF-CHECK
CONNECTOR(CN30)
TEST SWITCH
RAC-08PH
RAC-14PH1
1, RAC-10PH1
PH1, RAC- PH1,RAC-14PH1
104

Other manuals for Hitachi RAS-08PH1

Related product manuals