– 4 –
NAMES AND FUNCTIONS OF EACH PART
INDOOR UNIT
Air filter
To prevent dust from coming into the indoor unit.
(Refer page 16)
Front panel
Indoor unit indicators
Light indicator showing the operating condition.
(Refer page 5)
Horizontal deflector Vertical deflector
(Air Outlet)
(Refer page 15)
Remote controller
Send out operation signal to the indoor unit. So as
to operate the whole unit.
(Refer page 6)
MODEL NAME AND DIMENSIONS
About the outdoor unit:
When “Stop” is selected during operation
of the indoor unit, the fan of the outdoor
unit continues turning for 10 to 60
seconds to cool the electric parts down.
In heating operation, condensate or
water due to defrosting will flow.
Do not cover the drain port of the outdoor
unit because such water may freeze in
the chilly area.
When the outdoor unit is hung on the
ceiling, install the bush and drain pipe
on the drain port and drain water.
Air outlet
When “heating” operation is
performed, cool air blows and
when “cooling” or “dehumidifying”
operation is performed, warm air
blows.
Drain hose
Drains the dehumidified water from the indoor unit to the
outdoor during “cooling” or “dehumidifying” operation.
Piping and Wiring
Air inlets (Rear and left sides)
Drain port
(Bottom)
Earth terminal
(Lower section of the side)
Air outlet
When “heating” operation is
performed, cool air blows and
when “cooling” or “dehumidifying”
operation is performed, warm air
blows.
Drain hose
Drains the dehumidified water from the indoor unit to the
outdoor during “cooling” or “dehumidifying” operation.
Piping and Wiring
Air inlets (Rear and left sides)
Drain port
(Bottom)
Earth terminal
(Lower section of the side)
OUTDOOR UNIT
MODEL WIDTH (mm) HEIGHT (mm) DEPTH (mm)
780 280 21
700 505 258
750 548 288
79 2 2
RAS-08PH1, RAS-10PH1,
RAS-14PH1, RAS-18PH1
RAC-14PH1
RAC-18PH1
RAC-08PH1, RAC-10PH1
7
(
0
3
2
5$
5
<
6
:
,
7
&
+
RAC-08PH1
RAC-10PH1
RAC-14PH1
RAC-18PH1
8
600 9 9
– 5 –
NAMES AND FUNCTIONS OF EACH PART
INDOOR UNIT INDICATIONS
TIMER LAMP (Orange)
This lamp lights when the
timer is working.
OPERATION LAMP (Yellow)
This lamp lights during operation.
The OPERATION LAMP flashes
in the following cases during
heating.
(1) During preheating
For about 2-3 minutes after
starting up.
(2) During defrosting
Defrosting will be performed
about once an hour when frost
forms on the heat exchanger
of the outdoor unit, for 5-10
minutes each time.
TEMPORARY SWITCH
Use this switch to start and stop when the remote
controller does not work.
This temporary operation will be at the most recent
setting made. (The unit will immediately go into
automatic operation once power is switched on.)
CAUTION
Turn off the circuit breaker or pull out
the power plug if the unit is not be
operated for a long period.
If the power stays on and the unit is not operated, power is slightly consumed in the control circuit.
The power is saved by turning off the power switch (or the circuit breaker when the power is supplied
from the outdoor unit).
Attaching the Wasabi-Nano Titanium Air Cleaning
s Attach the
to the frame by gently compress its both sides
and release after insertion into filter frame.
s The cooling capacity is slightly weakened and
the cooling speed becomes slower when the
are used.
.
s
and reusable up to 20 times by using vacuum
cleaner or water rinse under running tap water.
When you want to renew it, please ask your sales
agent. Optional air cleansing and deodorizing
filters.
Frame
Air Filter
Claw
Filter Frame
Mesh (Accessories) to the filter frame.
Wasabi-Nano Titanium Air Cleaning Mesh
Wasabi-Nano Titanium Air Cleaning Mesh
Wasabi-Nano Titanium Air Cleaning Mesh
are washable
Wasabi-Nano Titanium Air Cleaning Mesh
7
(
0
3
2
5
$
5<
6
:,
7
&
+
ENGLISH
8